GV2ME07C technical identity and replacement considerations for TeSys Deca motor circuit breaker
GV2ME07C is the complete ordering reference for a Schneider Electric TeSys Deca motor circuit breaker. This page identifies the confirmed characteristics of GV2ME07C and the practical fit checks for an existing installation. The shared category collage is a reference image, not an exact photograph of GV2ME07C.
Technical parameters and confirmed identity
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | GV2ME07C |
| Product type | TeSys Deca motor circuit breaker |
| Adjustment | 1.6–2.5 A |
| Mechanism | Push-button operation |
| Function | Motor thermal-magnetic protection |
What the code identifies
The GV2ME07C designation identifies the part above, not every accessory in the complete system. Purchase and maintenance records should retain the exact GV2ME07C characters, including any suffix. Where a similar-looking reference exists, compare its full specification rather than treating it as an automatic replacement.
For GV2ME07C, the parameter table separates product identity from site-specific engineering decisions. Ratings in a family brochure may cover several variants; the installed GV2ME07C nameplate and current manufacturer data remain the final order check.
Application fit and engineering boundaries
Set protection to the motor nameplate current and verify starter coordination.
Before accepting GV2ME07C, compare the existing panel or machine drawing with the relevant voltage, current, contact, network, pressure or mechanical interface noted for this product. Record cable entry, mounting space, connected load and environmental conditions where applicable.
A procurement request for GV2ME07C should state the equipment tag and purpose, not just the part number. If the original unit has options or accessories, list them separately; a replacement GV2ME07C may not include those items.
Installation and functional record
Qualified personnel should isolate the equipment under the site's procedure before fitting GV2ME07C. Photograph the original connections, label conductors, and retain any software or parameter backup relevant to GV2ME07C.
After installation of GV2ME07C, test the operating sequence in a safe state. Record measured supply or signal values, status indications, alarms and the final GV2ME07C reference on the handover sheet.
If GV2ME07C is a safety, protection or switching component, complete the application-specific coordination and validation process. The information here is not a substitute for the machine risk assessment or electrical design review.
Similar-looking codes covered by this page
The following codes resemble GV2ME07C and are grouped here as reference variants, so they are not scheduled as separate product pages. Similar spelling does not mean electrical or mechanical interchangeability. Compare each full code, option and rating to GV2ME07C.
GV2ME05C
GV2ME08C
GV2ME20C
GV2ME0
GV2ME02
GV2ME03
GV2ME05
GV2ME06
GV2ME08
GV2ME20
GV2ME063
Order release checklist
For GV2ME07C, confirm the full designation, the actual installed interface, the rating or setting in the table, and the availability of any required mating part. Mark any deviation from the original GV2ME07C installation for engineering review.
The final GV2ME07C selection should be checked against current Schneider Electric product documentation and the delivered device label. Preserve the commissioning record with the order so future GV2ME07C service decisions remain traceable.