Schneider R9D87616: field dossier for Resi9 residual-current circuit breaker
R9D87616 is the exact designation used for this Resi9 residual-current circuit breaker entry. The picture is a shared Schneider-category reference collage, not an exact photograph of R9D87616. Use the confirmed details below as the starting point for enquiry; the installed label and current manufacturer document govern final selection.
Technical data and identification
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | R9D87616 |
| Product identity | Resi9 residual-current circuit breaker |
| Rated current | 16 A |
| Residual-current sensitivity | 30 mA |
| Pole arrangement | 1P+N |
| Curve and type | C curve, AC type |
Site information to collect
Before ordering R9D87616, write down the existing equipment tag, location and duty. Check earth-leakage protection type, breaking capacity and local installation rules. Capture a legible photograph of the complete R9D87616 marking so that voltage, option suffix and revision can be compared with the quotation.
Check the mating equipment around R9D87616: supply and load wiring, mechanical mounting, protection, communications or software interface as appropriate. The table intentionally separates documented facts from values that depend on a complete configured variant. Never infer a missing rating from a shared image or from another model whose code merely resembles R9D87616.
Quotation worksheet
- Complete R9D87616 designation and quantity
- Condition, revision and applicable manufacturer documentation
- Included accessories, exclusions and delivery region
- Any proposed substitution identified separately for approval
For R9D87616, ask the supplier to quote the exact reference and disclose any deviation. A suffix, pole count, communications port, certification or terminal style can change the installation even when the front appearance is similar. If the original R9D87616 is obsolete, confirm availability and obtain an engineering-reviewed migration path rather than assuming a current series is a direct swap.
Installation and commissioning record
Keep the isolation and safety procedure for the equipment that uses R9D87616. Compare delivered markings, package condition and accessories with the approved order. Record hardware and firmware revisions where present; preserve settings and backups before an installed R9D87616 is removed.
The acceptance test for R9D87616 should match its actual duty: switching or trip performance, protective settings, measured values, motion direction, software connection or busway continuity as applicable. Use qualified personnel and the manufacturer's commissioning instructions. A passing visual inspection alone does not prove that R9D87616 is correctly configured.
Similar-looking designations
No additional unassigned R9D-pattern code is indexed with R9D87616. A different complete designation still requires its own technical check.
Release decision
Approve R9D87616 for procurement only after the exact model, documented product role, site connections and supplier offer agree. Keep R9D87616 on the purchase and receiving records. If a substitute is proposed, document the differences and obtain approval before fitting it.