low voltage

Hotline

PowerLogic METSEPM3255 Schneider Electric DIN-Rail Power Meter | Three-Phase CT Metering, RS485 and Digital I/O

description:Schneider Electric METSEPM3255 PowerLogic PM3255 energy meter: ratings, installation checks, commissioning context and similar-looking ordering references....
BASIC INFO

METSEPM3255 power-meter installation: CT ratio, Modbus setup and digital points

Schneider Electric METSEPM3255 is a DIN-rail PowerLogic meter for three-phase electrical monitoring. Its readings depend on correct CT ratio, voltage wiring and communication setup. The shared power-metering collage is a category reference rather than an exact product photo of METSEPM3255.

Technical specification and selection data

Technical itemVerified value / selection note
Exact referenceMETSEPM3255
RangePowerLogic PM3000 / PM3255
MountingDIN rail
Current measurementExternal CT-operated three-phase meter
CommunicationsRS485 Modbus
Digital points2 digital inputs and 2 digital outputs
MeasurementEnergy and key electrical quantities; confirm configured wiring system

Metering accuracy starts at wiring

Confirm each CT orientation, secondary rating, phase association and voltage connection before relying on METSEPM3255 data. Configure the CT ratio and system type to match the installed network. A plausible-looking reading can still be wrong if the phase sequence or transformer ratio is incorrect.

Integrate the data

Document METSEPM3255 RS485 address, baud rate, parity and the supervisory system's Modbus register map. Assign its digital inputs and outputs to the intended status or pulse functions. Verify trends and alarms against a known load after any replacement.

Commission and document

Use appropriate electrical isolation and CT-secondary handling procedures when installing METSEPM3255. Record nameplate, firmware, settings, network identifier and a baseline reading. A visually similar PM-series meter may have different communication or I/O features.

Similar-looking Schneider references

The following codes resemble METSEPM3255 in naming or appearance. Ratings, functions and connection details can differ; they are comparison references, not guaranteed substitutes for METSEPM3255.

METSEPM5560, METSEPM5650, METSEPM2130, METSEPM2210, METSEPM2220, METSEPM2230, METSEPM5100, METSEPM5110, METSEPM5310, METSEPM5330

Before placing an order

Specify METSEPM3255 with its CT requirements, network protocol and digital I/O needs. Compare the complete reference before accepting another PowerLogic unit in place of METSEPM3255.

For METSEPM3255, confirm the printed designation, current Schneider Electric documentation, installation conditions and any lifecycle notice before purchase or commissioning.

Additional Schneider METS visually similar model codes

These ordering strings are grouped because their printed model codes look similar. They may represent different product types, functions, ratings, accessories or approvals. This list is not an interchangeability claim; verify the exact manufacturer data before ordering.

  • METSE3PM5560
  • METSEIP65OP96X96FF
  • METSEPM2KANLGIO22
  • METSEPM2KDGTLIO22
  • METSEPM8240
  • METSEPM8244

Additional METS visually similar written designations

These entries include brackets, slashes, commas or other printed notation from the requested model list. The notation may describe a configuration or accessory rather than a single orderable part. They are grouped by their visible code pattern only, not by interchangeable technical function. Confirm the actual manufacturer designation and rating before ordering.

  • METSE3PM5560 (PM5660)

 

 

Pre:Schneider Electric ATS01N106FT Altistart 01 Compact Soft Starter | 6 A, 110–480 V Motor Supply and Starting-Control Guide Next:Schneider Electric XVBC2B3 Harmony XVB Stack-Light Unit | Green Steady LED, 70 mm and 24 V AC/DC