Selecting LC1D09BD for a three-phase motor starter with 24 V DC control
Schneider Electric LC1D09BD is a TeSys Deca non-reversing contactor used to switch three-phase motor loads. The power contacts, 24 V DC control coil and integrated auxiliary contacts must all match the starter circuit. The category montage illustrates the product family and is not a unique photo of LC1D09BD.
Key technical data
| Technical item | Verified value / selection note |
|---|---|
| Complete reference | LC1D09BD |
| Range | TeSys Deca (TeSys D) contactor |
| Main poles | 3 normally open power poles |
| Motor-duty rating | 9 A AC-3/AC-3e; 4 kW at 400 V for the stated duty |
| Control coil | 24 V DC |
| Built-in auxiliaries | 1 NO + 1 NC |
| Terminations | Screw-clamp connections; confirm installed cable and accessory arrangement |
Start with the control circuit
For LC1D09BD, confirm that the control supply is 24 V DC at the coil terminals. A contactor with a nearly identical LC1D09 reference may use a different coil voltage, so matching the nine-ampere frame alone is unsafe. Check any surge suppression, PLC output capacity and stop-chain arrangement.
Motor and contact duty
The LC1D09BD 9 A AC-3/AC-3e rating addresses a specified motor-switching duty. Compare motor full-load current, voltage, start frequency, ambient conditions and coordination with the overload protection. Do not read the 9 A figure as permission to use the device for every resistive or mixed-load circuit.
Auxiliary and mechanical fit
Confirm the required 1 NO + 1 NC auxiliary functions and any fitted front or side blocks. Check enclosure space, mounting, terminal style and the wiring schematic before changing LC1D09BD. A replacement can fit the rail but still disagree with the control logic if an auxiliary position or coil code differs.
Service handover
When requesting LC1D09BD, provide the complete label, motor power, control voltage and an image of connected auxiliaries and overload relay. After replacement, verify contactor pick-up and drop-out, motor rotation, interlocks and overload trip behavior under the site's approved commissioning procedure.
Similar-looking model references
These LC1D09-looking references are grouped for identification. Coil, contact, terminal, market or accessory details may differ; do not assume direct substitution for LC1D09BD.
LC1D09, LC1D09B7, LC1D09BL, LC1D09D7, LC1D09E7, LC1D09F7, LC1D09G7, LC1D09M7, LC1D09P7, LC1D09U7, LC1D09MD, LC1D09BD24, LC1D09M7C, LC1D09FDC, LC1D09AF7
Final order check
For LC1D09BD, confirm the complete printed code, installed wiring, application ratings and current Schneider Electric product documentation before purchase or commissioning.
Additional Schneider LC1 visually similar model codes
These ordering strings are grouped because their printed model codes look similar. They may represent different product types, functions, ratings, accessories or approvals. This list is not an interchangeability claim; verify the exact manufacturer data before ordering.
- LC1 D09-D38 LAD9R1
- LC1 N1810
- LC1 NO910
- LC1-D 3P 12A
- LC1-D 3P 18A
- LC1-D 3P 32A
- LC1-D 3P 40A
- LC1-D 3P 50A
- LC1-D 3P 65A
- LC1-D 3P 80A
- LC1-D0901M7
- LC1-D09BL
- LC1-D09M7
- LC1-D09P7
- LC1-D11500
- LC1-D128BD
- LC1-D12BL
- LC1-D12M7C
- LC1-D12P7
- LC1-D150M7C
- LC1-D1801
- LC1-D1810 220V
- LC1-D18BL
- LC1-D25
- LC1-D25008-G7
- LC1-D258BD
- LC1-D25BL
- LC1-D25M7
- LC1-F22P7
- LC1-F265P7
- LC1-N1810M5N
- LC1-N2501M5N
- LC165AM7
- LC1N0601
- LC1N0910M5N
- LC1N1201
- LC1N1201M5N
- LC1N1810M5
- LC1N1810M5N
- LC1N2501M5N
- LC1N2510
- LC1N2510F5N
- LC1N3201M5N
- LC1N3801M5N
- LC1N3810
- LC1N40M5N
- LC1N65M5N
- LC1N80E5N
- LC1R2510
- LC1R2510M5N
Additional LC1 visually similar written designations
These entries include brackets, slashes, commas or other printed notation from the requested model list. The notation may describe a configuration or accessory rather than a single orderable part. They are grouped by their visible code pattern only, not by interchangeable technical function. Confirm the actual manufacturer designation and rating before ordering.
- LC1-D40, 220V
- LC1D18, 380V
- LC1D80, 95A, 380V
Additional similar-looking designations
LC1 contactor-style designations are indexed here for search and enquiry. They may designate different hardware, functions or configurations and are not automatically interchangeable. Check each exact reference, rating and manufacturer record.