LC1D093B7 buying and fit brief for TeSys Deca three-pole contactor
Use this LC1D093B7 brief to identify the Schneider Electric TeSys Deca three-pole contactor, compare verified catalog characteristics and define what must be checked at the site. The shared collage is a category reference image; it does not depict the exact LC1D093B7 configuration.
Key technical data
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | LC1D093B7 |
| Product family | TeSys Deca three-pole contactor |
| AC-3 current | 9 A at up to 440 V AC |
| Coil | 24 V AC, 50/60 Hz |
| Terminals | Spring terminals |
Buyer question: what must match?
Start with the complete LC1D093B7 code, not only a family name. Compare the fitted item's nameplate with the proposed LC1D093B7 supply, rating, terminals, mounting and accessories. A close-looking suffix can change the electrical or mechanical interface.
For LC1D093B7, document the actual panel or machine duty and any associated drawing. Confirm the motor duty and the 24 V AC control circuit. When the application is safety-related, have a qualified engineer assess the complete function and applicable design requirements.
At the equipment
Photograph the existing LC1D093B7 installation before removal. Record the cable labels, environmental exposure, protective devices and available clearance. If LC1D093B7 is part of an automation assembly, back up relevant settings and record the matching controller, drive or accessory revision.
Do not infer drop-in interchangeability from the image or the LC1D093B7 family description. Confirm the current manufacturer data and installation manual for the exact LC1D093B7 variant; compare the delivered nameplate before work begins.
Order and commissioning notes
The purchasing request for LC1D093B7 should state the full code, quantity, required accessories and the intended equipment tag. For legacy equipment, confirm regional availability and lifecycle status rather than assuming that a historically used LC1D093B7 remains the preferred replacement.
After qualified personnel install LC1D093B7 under site isolation procedures, check wiring, settings and functional response against the approved drawing. Keep the test record with the LC1D093B7 designation for subsequent service.
Related-looking model codes
These 18 LC1D0-pattern codes resemble LC1D093B7 and are indexed on this representative page instead of receiving separate pages in this publishing set. They are not declared equivalent to LC1D093B7; verify every complete code and option string.
Release decision
Release the LC1D093B7 order only after the exact rating, matching accessories and fit are confirmed. Retain the LC1D093B7 data record and commissioning evidence so future maintenance can distinguish this exact variant from adjacent codes.