9036DG2 float switch: liquid rise action and tank installation
Selecting 9036DG2 starts with the complete code, not a similar-looking faceplate. As a open-tank float switch, 9036DG2 must be checked against the host equipment, supply and intended function. The main image is a shared category reference rather than an exact 9036DG2 image.
Reference and rating snapshot
| Technical item | Verified value / selection note |
|---|---|
| Exact ordering code | 9036DG2 |
| Product family | open-tank float switch |
| Application | Open-tank liquid-level control |
| Contact action | Close on liquid rise |
| Poles | 2 |
| Enclosure | NEMA 1 class |
Before energizing or commissioning
Inspect float linkage, rod kit, tank geometry and wiring clearances. Commission by moving through both levels and observing the real controlled device.
For 9036DG2, compare the exact nameplate, wiring diagram and manufacturer literature before allowing a substitution. A close-looking suffix can change ratings, interface or delivered components.
What to confirm on the installed unit
Confirm the required contact action: this model closes on liquid rise. A visually similar float switch can reverse the pump sequence if its action differs.
Document the existing 9036DG2 circuit, accessories and setpoints before removing hardware. Use the site's isolation and commissioning procedures, and preserve the approved engineering record.
On-site replacement notes
Inspect float linkage, rod kit, tank geometry and wiring clearances. Commission by moving through both levels and observing the real controlled device.
The final choice of 9036DG2 depends on the actual installation. Check ambient conditions, available space, mating parts and local electrical requirements rather than inferring fit from appearance.
Application fit
Confirm the required contact action: this model closes on liquid rise. A visually similar float switch can reverse the pump sequence if its action differs.
After fitting 9036DG2, verify the intended function under representative operating conditions and record the result. A matching code does not eliminate the need for a functional check.
Similar-looking reference codes
No sufficiently similar, unassigned Schneider reference was found for 9036DG2 in this publishing set. Do not substitute an unrelated code simply because its housing resembles 9036DG2.
Quote and acceptance
When requesting 9036DG2, include the exact 9036DG2 label, site voltage, connected equipment, installation photo and required quantity. State whether original 9036DG2 stock or a documented engineering alternative is acceptable. Ask the supplier to confirm current availability, accessories and manufacturer documentation.
Before releasing 9036DG2 to site, compare the delivered full code and terminal/connector arrangement with the approved bill of materials. Keep 9036DG2 associated with its original application and obtain qualified review if any rating, function or lifecycle status differs.