Schneider 65306 | identification and field-fit notes for MasterPact NT MicroLogic 6.0 A control unit
65306 is a Schneider Electric reference for MasterPact NT MicroLogic 6.0 A control unit. The shared main image illustrates the relevant category, not the exact 65306 item. The full manufacturer code should be the purchasing and receiving reference; visual similarity alone is not a compatibility test.
Verified technical record
| Technical item | Verified value / selection note |
|---|---|
| Exact reference | 65306 |
| Manufacturer | Schneider Electric |
| Product identity | MasterPact NT MicroLogic 6.0 A control unit |
| Protection functions | LSIG |
| Measurement | Ammeter |
| Mounting context | MasterPact NT drawout |
What to verify before ordering
Start with the installed nameplate or packaged label for 65306. Record the complete code, quantity, location and equipment revision. For 65306, check the electrical and mechanical ratings shown in the verified record, then compare them to the actual circuit duty and the applicable manufacturer installation instructions.
Request the exact reference, manufacturer documentation, accessory list, lifecycle/stock status and a written statement of any substitution.
A quotation for 65306 should distinguish a new original component from a surplus or repaired unit. Ask for the exact 65306 marking on the offered product. Where an older reference is no longer marketed, an alleged successor requires an explicit fit and protection review before approval.
Physical and electrical fit
Confirm the enclosure, rail or panel mounting, terminal access and available clearances for 65306. A number on a list does not establish terminal orientation, pole arrangement, wire size, fuse type, or trip-unit pairing. Verify the exact configuration of 65306 against the existing assembly, not against a nearby catalogue number.
For switching and protection items, check voltage, current, breaking or sensing duty and coordination with upstream and downstream equipment. For the metering and control versions of 65306, confirm sensor, wiring, supply and output details. Only the properties stated in the table above are treated as documented for 65306; any unlisted value remains to be checked.
Receiving and commissioning sequence
- Match the delivered designation with the purchase order and inspect packaging.
- Confirm documented ratings and the intended installation point.
- Install under the site isolation procedure and manufacturer instructions.
- Record the acceptance test, settings and final equipment tag.
Before fitting 65306, preserve settings, drawings and photographs of the original arrangement where relevant. Commissioning should test the actual function of 65306 in its installed context. A part that looks correct may still have a different rating, contact state, release voltage or protection characteristic.
Similar-looking catalogue references
No other currently unassigned 653-prefix catalogue number is placed with 65306. This does not imply that different suffixes are interchangeable.
Decision note
Release 65306 for purchase only after the code, documented identity, installation duty and supplier offer agree. Keep 65306 in the order and acceptance record. Any proposed substitute should be evaluated separately rather than silently changing the reference.