description:Schneider Electric 56173 VigiPacT RH99M earth-leakage relay: key ratings, application and service notes, related references....
BASIC INFO

Field guide to 56173, the Schneider VigiPacT RH99M earth-leakage relay

56173 is a Schneider Electric reference for VigiPacT RH99M earth-leakage relay. The shared main image illustrates the relevant category, not the exact 56173 item. The full manufacturer code should be the purchasing and receiving reference; visual similarity alone is not a compatibility test.

Verified technical record

Technical itemVerified value / selection note
Exact reference56173
ManufacturerSchneider Electric
Product identityVigiPacT RH99M earth-leakage relay
ResetManual
Sensitivity range0.03 to 30 A
Time setting0 to 4.5 s

What to verify before ordering

Start with the installed nameplate or packaged label for 56173. Record the complete code, quantity, location and equipment revision. For 56173, check the electrical and mechanical ratings shown in the verified record, then compare them to the actual circuit duty and the applicable manufacturer installation instructions.

Purchasing checkpoint
Request the exact reference, manufacturer documentation, accessory list, lifecycle/stock status and a written statement of any substitution.

A quotation for 56173 should distinguish a new original component from a surplus or repaired unit. Ask for the exact 56173 marking on the offered product. Where an older reference is no longer marketed, an alleged successor requires an explicit fit and protection review before approval.

Physical and electrical fit

Confirm the enclosure, rail or panel mounting, terminal access and available clearances for 56173. A number on a list does not establish terminal orientation, pole arrangement, wire size, fuse type, or trip-unit pairing. Verify the exact configuration of 56173 against the existing assembly, not against a nearby catalogue number.

For switching and protection items, check voltage, current, breaking or sensing duty and coordination with upstream and downstream equipment. For the metering and control versions of 56173, confirm sensor, wiring, supply and output details. Only the properties stated in the table above are treated as documented for 56173; any unlisted value remains to be checked.

Receiving and commissioning sequence

  1. Match the delivered designation with the purchase order and inspect packaging.
  2. Confirm documented ratings and the intended installation point.
  3. Install under the site isolation procedure and manufacturer instructions.
  4. Record the acceptance test, settings and final equipment tag.

Before fitting 56173, preserve settings, drawings and photographs of the original arrangement where relevant. Commissioning should test the actual function of 56173 in its installed context. A part that looks correct may still have a different rating, contact state, release voltage or protection characteristic.

Similar-looking catalogue references

No other currently unassigned 561-prefix catalogue number is placed with 56173. This does not imply that different suffixes are interchangeable.

Decision note

Release 56173 for purchase only after the code, documented identity, installation duty and supplier offer agree. Keep 56173 in the order and acceptance record. Any proposed substitute should be evaluated separately rather than silently changing the reference.

 

 