ABB ACS800-01-0030-3 | 30 kW Continuous Rating, 55 A and 380–415 V Supply Class

description:Technical identification and selection guidance for ABB ACS800-01-0030-3, including verified family data, system compatibility and configuration checks....
BASIC INFO

ACS800-01-0030-3 drive: current rating, duty and retrofit compatibility

The ABB ACS800-01-0030-3 is a wall-mounted industrial drive designation for a 380–415 V three-phase supply class. ABB identifies a maximum continuous output of 30 kW and 55 A for this product. Actual permissible motor duty depends on ambient conditions, switching frequency, overload profile, installation and fitted options; verify the drive nameplate and manual before engineering use.

Key technical data

Technical itemVerified value / selection note
Type designationACS800-01-0030-3
ABB product ID64576291
Continuous output power30 kW maximum reference
Continuous output current55 A maximum reference
Supply class380–415 V three-phase family designation
ConstructionWall-mounted ACS800-01 drive; frame and options depend on configuration
Lifecycle checkConfirm current support, firmware and approved replacement pathway

The table summarizes family or catalog values for identification and initial selection. Confirm the nameplate, environmental limits, standards, revision and options for the exact device before procurement or engineering approval.

Application and system selection

The ACS800 is used in industrial speed-control systems where drive behavior, application macros, fieldbus links and parameter continuity may be important. Identify the driven load, motor data, duty cycle, braking needs and control architecture before quoting a replacement. Older installations may depend on optional boards or legacy firmware that are not evident from the base code.

Configuration and compatibility

Check the complete order code for EMC filter, brake chopper, fieldbus and I/O options, plus frame, cooling and cabinet clearances. Confirm supply fault level and upstream protection. Treat a newer ACS family as a potential migration project rather than a drop-in replacement until parameters, interfaces and safety design are reviewed.

Related models and order-code references

The following designations are related catalog references, not automatic substitutes. Check each complete code, rating, connection, revision and application requirement before selecting a variant.

  • ACS800-01 64379879
  • ACS800-01-0003-3
  • ACS800-01-0004-3
  • ACS800-01-0009-3+E200+K454+L502+L503
  • ACS800-01-0016-3+E200+K458+L503+P904
  • ACS800-01-0016-5+P901
  • ACS800-01-0025-3+D150+P901
  • ACS800-01-0025-3+D150+R454+L508+P901+P904+R711
  • ACS800-01-0030-3+D150+K466
  • ACS800-01-0030-3+E200+K454+LB03
  • ACS800-01-0030-3+E200+P901
  • ACS800-01-0030-5+B056+C132+E200+P904
  • ACS800-01-0040-3+200+K466+L501+P901+Q967+R711
  • ACS800-01-0040-3+B056+D150+E200+P901
  • ACS800-01-0040-3+E200
  • ACS800-01-0040-7+K454
  • ACS800-01-0050-3+E200+L503
  • ACS800-01-0060-3+B056+D150
  • ACS800-01-0060-5+E200
  • ACS800-01-0070-7+D150+E210+P901
  • ACS800-01-0100-3
  • ACS800-01-0100-3 +D150 +P901
  • ACS800-01-0100-3+D150+P901
  • ACS800-01-0120-3+D150
  • ACS800-01-0120-3+D150+E210+K454+L508+P901+P904
  • ACS800-01-0165-3+P901
  • ACS800-01-0205-7

Installation and commissioning

Follow the ACS800 hardware manual for isolation, DC-link discharge and lifting/handling. Inspect cooling paths, fans, terminals and protective earth, then back up parameters before changing hardware. Commission with motor data, control sources, limits and protection settings verified; validate communication and machine interlocks before loaded operation.

Replacement and procurement information

For a quotation or replacement review, provide the complete designation ACS800-01-0030-3, the order code where applicable, serial or hardware revision, quantity, operating environment, connected equipment and required delivery date. Include a legible nameplate image and relevant wiring, loop or switchgear drawing so the exact interface and configuration can be checked.

Ask the supplier to confirm accessories, revision compatibility and any approved successor in writing. Do not select solely from a family name or product photograph. Follow the current ABB installation and safety instructions for the exact unit.

 

 

Pre:ABB TSP311.A1.K1.N2.Z9(L: 290 MM.).S1.D6.P2.S1.L4.H5.T1.AZ | 290 mm Assembly and Process Connection Review Next:ABB DCS800-S02-0260-04 | 260 A Armature Rating and Industrial Retrofit Checks