low voltage

Hotline

MTL5576-THC 2channel Temperature converter, THC for sale

description:MTL4576-THC – MTL5576-THC TEMPERATURE CONVERTER mV/THC input, 2-channel...
BASIC INFO
Production overviews
       
                                 MTL 5500 Intrinsically Safe Isolators  MTL5576-THC

MTL4576-THC – MTL5576-THC TEMPERATURE CONVERTER mV/THC input, 2-channel
The MTLx576–THC converts low–level dc signals from temperature sensors mounted in a hazardous–area into 4/20mA currents for driving safe–-area loads. Software selectable features include linearisation for standard thermocouple types, ranging, monitoring, testing and tagging. Configuration is carried out using a personal computer. The hazardous–area connections include cold–junction compensation and do not need to be ordered separately.

                                    



MTL5576-THC product specification
SPECIFICATION
See also common specification
Number of channels
Two
Signal source
THC types J, K, T, E, R, S, B or N to BS 60584 and XK
mV input
Location of signal source
Zone 0, IIC, T4–6 hazardous area
Division 1, Group A, hazardous location
Input signal range
–75 to +75mV
Input signal span
3 to 150mV
Cold junction compensation
Automatic or selectable
Cold junction compensation error
≤ 1.0°C
Common mode rejection
120dB for 240V at 50Hz or 60Hz
Series mode rejection
40dB for 50Hz or 60Hz
Calibration accuracy (at 20°C)(includes hysteresis, non-linearity and repeatability)
Input: ±15µV or ±0.05% of input value
(whichever is greater)
Output: ±16µA
Temperature drift (typical)
Input: ±0.003% of input value/°C
Output: ±0.6µA/°C
Safety drive on sensor burnout
Upscale, downscale, or off
Output range
4 to 20mA nominal into 300Ω max.
Maximum lead resistance
300Ω with safety drive on sensor failure enabled
>10kΩ with safety drive on sensor failure disabled
Response time
Configurable - 500 ms default
(Accuracy at 100/200ms - contact Eaton's MTL product line)
LED indicator
Green: power and status indication
Yellow: one provided for channel status
Red: alarm indication
Power requirement, Vs with 20mA signal
60mA at 24V
Power dissipation within unit with 20mA signal
1.4W at 24V
Isolation
Functional isolation channel–channel for safe and hazardous–area
circuits.
Safety description
Refer to certificate for parameters. Um=253V rms or dc
Configurator
A personal computer running MTL PCS45 software with a
PCL45USB serial interface.



Other related models for MTL5576 as below for your reference.
MTL5018AC
MTL5501-SR
MTL5510
MTL5510B
MTL5511
MTL5513 
MTL5514
MTL5514D
MTL5516C
MTL5517
MTL5521
MTL5522
MTL5523
MTL5523V – V
MTL5524
MTL5525
MTL5526
MTL5541
MTL5541A
MTL5541AS 
MTL5541S
MTL5544
MTL5544A
MTL5544AS
MTL5544D
MTL5544S
MTL5546
MTL5546Y
MTL5549
MTL5549Y
MTL5573
MTL5575
MTL5576-RTD
MTL5576-THC
MTL5581
MTL5582
MTL5582B
MTL5991 
MTL5531
MTL5532
MTL5533
MTL5561
MPA5500
MTL5051
MTL5053
MTL5314
MTL5599 
 
For more information about MTL5576 isolators, please feel free to contact me here.
Contact details

HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85880977
Mobile :86-13545206420(Whatapp&Wechat is available)
Fax:86-027-85309780
Skype:Diana@hkxytech.com
E-mail:Diana@hkxytech.com    Or Cc:
Dianatian118@gmail.com
Website:www.hkxy-lowvoltage.com












Pre:MTL5576-RTD 2channel Temperature converter, RTD for sale. Next:MTL5581 1channel mV/THC isolator for low-level signals