low voltage

Hotline

MTL4523R Solenoid driver with LFD MTL4523R safe isolator

description:MTL4523/R – MTL5523 SOLENOID/ALARM DRIVER with line fault detection, IIC...
BASIC INFO
Production overviews
       
                                 MTL 4500 Intrinsically Safe Isolators  MTL4523R

MTL4523/R – MTL5523 SOLENOID/ALARM DRIVER with line fault detection, IIC
With the MTLx523 interface, an on/off device in a hazardous area can be controlled by a volt-free contact or logic signal in the safe area. It is suitable for driving loads such as solenoids. Line fault detection (LFD), which operates irrespective of the output state, is signalled by a safearea solid-state switch which de-energises MTLx523, or energises MTL4523R, if a field line is open or short–circuited. Earth fault detection can be provided by connecting an MTL4220 earth leakage detector to terminal 3.

                                


MTL4523R safe isolator product specification
SPECIFICATION
See also common specification
Number of channels
One
Location of load
Zone 0, IIC, T4–6 hazardous area if suitably certified
Div. 1, Group A, hazardous location
Minimum output voltage Equivalent output circuit
22.2
22.2
13.6
Hazardous-area output
Minimum output voltage: 13.6V at 48mA
Maximum output voltage: 24V from 180Ω
Maximum off-state output voltage: 4V from 180Ω
Current limit: 48mA minimum
Output ripple
< 0.5% of maximum output, peak to peak
Control input
Suitable for switch contacts, an open collector transistor or logic drive.
(Internal contact wetting voltage 12V @ 0.2mA contact closed.
Not suitable for voltage control via series diode.)
Output turns on if input switch closed, transistor on or
< 1.4V applied across control input
Output turns off if input switch open, transistor off or
> 4.5V applied across control input
Response time
Output within 10% of final value within 100ms
Line fault detection (LFD)
Open or short circuit in field cabling de-energises* solid state
line-fault signal.
LFD transistor is switched on*, provided that the field circuit
impedance is > 55Ω and < 4kΩ.
* These conditions are reversed for the MTL4523R. This is to permit parallel
connection of alarms between modules to provide a group alarm output.
Line fault signal characteristics
Maximum off-state voltage: 35V
Maximum off-state leakage current: 10µA
Maximum on-state voltage drop: 2V
Maximum on-state current: 50mA
LED indicators
Green: power indication
Yellow: output status, on when output active
Red: LFD indication, on when line fault detected
Maximum current consumption
100mA at 24V dc
Power dissipation within unit
1.2W with typical solenoid valve, output on
2.0W worst case
Safety description
Uo=25V Io=147mA Po= 0.92W Um = 253V rms or dc


Other related product models as below for your reference.

MTL4501-SR       
MTL4504                
MTL4510              
MTL4510B                
MTL4511
MTL4513             
MTL4514D             
MTL4514_B          
MTL4516                   
MTL4516C
MTL4517             
MTL4521                
MTL4521L            
MTL4523                  
MTL4523L
MTL4523R           
MTL4523V-VL        
MTL4524              
MTL4524S                
MTL4525  
MTL4526             
MTL4541                
MTL4541A            
MTL4541AS              
MTL4541B
MTL4541P           
MTL4541S              
MTL4541T            
MTL4544                  
MTL4544A
MTL4544AS         
MTL4544B               
MTL4544D           
MTL4544S                 
MTL4546
MTL4546C           
MTL4546S              
MTL4546Y            
MTL4549                  
MTL4549C
MTL4549Y           
MTL4573                
MTL4575              
MTL4576-RTD           
MTL4576-THC
MTL4581             
MTL4582B              
MTL4531              
MTL4532                   
MTL4561
MTL4599             
MTL4599N



If you have any other question about MTL4523R, please kindly send me an inquiry, or chat with  me on line!
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85880977
Mobile :86-13545206420(Whatapp&Wechat is available)
Fax:86-027-85309780
Skype:Diana@hkxytech.com
E-mail:Diana@hkxytech.com    Or Cc:
Dianatian118@gmail.com
Website:www.hkxy-lowvoltage.com











Pre:MTL4523L Loop powered solenoid driver+ LFD MTL4523 isolator Next:MTL4523V-VL Solenoid/Alarm driver with voltage controli