How the exact SB3,5-E2 designation fits the system

Pepperl+Fuchs SB3,5-E2 is a inductive slot sensor used to detect a metal flag passing through a narrow slot. This page keeps the exact SB3,5-E2 designation visible for buyers and maintenance personnel. The shared product main image is a category montage, not an exact photograph of SB3,5-E2. Confirm the latest manufacturer record and installed label before using any figure to specify a replacement.

Technical data and selection limits

Technical itemVerified value / selection note
Exact modelSB3,5-E2
Product roleinductive slot sensor
Slot width3.5 mm
OutputPNP normally open, 3-wire DC
Supply10 to 30 V DC
Switching frequencyUp to 3000 Hz
Variant checkConfirm the complete designation and current manufacturer documentation before replacement.

Mounting and connection

Before installation of SB3,5-E2, Verify target depth, PNP input polarity and flag clearance. Inspect the exact terminals, mechanical engagement and clearance against the manufacturer's drawing. If the installation is Ex-rated or safety-related, validate the complete certified circuit and site procedure. Do not copy limits from a visually similar suffix onto SB3,5-E2.

Purpose in the process

The operational role of SB3,5-E2 is to detect a metal flag passing through a narrow slot. Document the expected input condition and the required output or mechanical response. A change in host electronics, wiring, hazardous-area classification or process medium can alter whether SB3,5-E2 remains suitable. Similar-looking designations listed below are inventory references only, not declared substitutes.

Installed assembly

For SB3,5-E2, start with the real installation rather than the appearance of a similar component. Record the mating device, drawing revision, power supply, connection, mounting position and environmental conditions. The complete SB3,5-E2 code is the ordering key. Accessories and certificates may be separate line items, so request confirmation of the entire installed assembly.

Order description

An enquiry for SB3,5-E2 should include the exact printed code, quantity, host or mating accessory, approval need and a label photograph. The technical table identifies confirmed values for SB3,5-E2; any uncertain variant choice is explicitly a verification item. Request the appropriate document for every alternative suffix and retain the approved selection with the maintenance file.

Functional acceptance

To accept SB3,5-E2, observe a known normal state and a known changed state at the connected host. Record the measured values, output indication and controller response. Where adjustment or configuration exists, preserve its settings before removing the former unit. Check the working-range edge and repeat the test after final mechanical fixing of SB3,5-E2.

Other visually related designations

Codes below resemble SB3,5-E2 in print but may differ in function, ratings, fit or approvals. Verify each full designation independently.

No additional same-pattern designation is grouped with SB3,5-E2 here.

Service close-out

Handover for SB3,5-E2 is complete only when the fitted marking, drawing, test result and purchasing record match. Keep the photos and settings so a later team can recognize SB3,5-E2 without guessing from the shared image or the related-code index.

 

 