low voltage

Hotline

ABB OTP63T3M(1SCA022608R2910) Enclosed Three-Pole Safety Disconnector — Parameters, Interfaces and Test Plan

description:Technical identification and selection guidance for ABB OTP63T3M(1SCA022608R2910), including verified family data, system compatibility and configuration checks....
BASIC INFO

ABB OTP63T3M(1SCA022608R2910) selection decision record

Start the ABB OTP63T3M(1SCA022608R2910) enquiry with a precise equipment identity and a defined plant function. The verified values below establish a technical baseline; they do not replace checking the delivered unit.

Verified parameters and fit limits

Technical itemVerified value / selection note
Complete designationOTP63T3M(1SCA022608R2910)
Product familyOTP63T3M
Component roleenclosed three-pole safety disconnector
TypeOTP63T3M
Order code1SCA022608R2910
Poles3
Current class63 A
EnclosurePlastic IP65 catalog version
AuxiliaryConfirm fitted 2 NO + 2 NC contacts
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

Before signing off OTP63T3M(1SCA022608R2910), check the current ABB documentation and the actual nameplate. Family-level information must not be used as a guaranteed option for every configuration.

What changes at installation?

Installing OTP63T3M(1SCA022608R2910) may affect adjacent wiring, panel access and auxiliary accessories. Check clearance and isolate the correct energy sources under the site's permit system.

Before disturbing OTP63T3M(1SCA022608R2910), save photos, configuration, parameter values and an alarm baseline. Keep removed parts identifiable until acceptance is signed.

What problem does it solve?

ABB OTP63T3M(1SCA022608R2910) is selected to isolate a machine from its local enclosure. State the actual circuit, loop or motor tag and the operating problem before deciding on a replacement.

A request for OTP63T3M(1SCA022608R2910) without site duty, installed revision or failure evidence can lead to a technically different part being offered.

Which interfaces must match?

For OTP63T3M(1SCA022608R2910), confirm load duty, cable entries, lockout and auxiliary wiring. Compare the original label, mounting, field terminals and power/control supplies with the ABB product reference.

Keep the OTP63T3M(1SCA022608R2910) electrical or network interface unchanged unless engineering has approved the revised drawing, settings and test scope.

What can cause a poor match?

A OTP63T3M(1SCA022608R2910) suffix or order-code difference may identify another coil, contact set, protocol, release, shaft or voltage. A matching appearance is not interchangeability evidence.

If the supplied OTP63T3M(1SCA022608R2910) differs from the approved item, quarantine it for review rather than changing field wiring to make it fit.

How is performance proved?

After approved installation of OTP63T3M(1SCA022608R2910), check handle, isolation and auxiliary states. Use only documented safe test methods and include connected equipment behavior.

Record the OTP63T3M(1SCA022608R2910) as-left results, asset tag, revision, date and witness. Restore alarms, interlocks and normal control before service handover.

What should purchasing retain?

The ABB OTP63T3M(1SCA022608R2910) record should include the complete designation, required accessories, label evidence and the current installation manual revision.

For any proposed substitute to OTP63T3M(1SCA022608R2910), obtain written confirmation of every changed technical characteristic and the site's acceptance.

Other codes in this same series

The following OTP63T3M references can accompany an ABB OTP63T3M(1SCA022608R2910) enquiry. Suffix changes can affect ratings, fit or approvals, so none is an automatic replacement.

No other unassigned OTP63T3M reference is grouped with OTP63T3M(1SCA022608R2910) in this release.

Enquiry and acceptance handoff

Quote ABB OTP63T3M(1SCA022608R2910) exactly, include the asset tag and duty, and request confirmation of any missing accessories or alternative build.

Keep the approved OTP63T3M(1SCA022608R2910) comparison, installation checks and test results in the maintenance record.

 

 

Pre:ABB OT16F3 | Three-Pole Non-Fusible Disconnect Switch Compatibility and Service Guide Next:Replacement Decision for ABB EF460-500 150–500 A Electronic Motor Overload Relay