Start the ABB OT16F3 enquiry with a precise equipment identity and a defined plant function. The verified values below establish a technical baseline; they do not replace checking the delivered unit.
Verified parameters and fit limits
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | OT16F3 |
| Product family | OT16F3 |
| Component role | three-pole non-fusible disconnect switch |
| Type | OT16F3 |
| Order code | 1SCA104811R1001 |
| Poles | 3 |
| Catalog type | 16 A class; UL/CSA listing 20 A |
| Mount | Base or DIN rail |
| Handle/shaft | Not included |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
Before signing off OT16F3, check the current ABB documentation and the actual nameplate. Family-level information must not be used as a guaranteed option for every configuration.
What problem does it solve?
ABB OT16F3 is selected to provide local manual isolation. State the actual circuit, loop or motor tag and the operating problem before deciding on a replacement.
A request for OT16F3 without site duty, installed revision or failure evidence can lead to a technically different part being offered.
What can cause a poor match?
A OT16F3 suffix or order-code difference may identify another coil, contact set, protocol, release, shaft or voltage. A matching appearance is not interchangeability evidence.
If the supplied OT16F3 differs from the approved item, quarantine it for review rather than changing field wiring to make it fit.
Which interfaces must match?
For OT16F3, confirm utilization category, upstream protection and handle. Compare the original label, mounting, field terminals and power/control supplies with the ABB product reference.
Keep the OT16F3 electrical or network interface unchanged unless engineering has approved the revised drawing, settings and test scope.
How is performance proved?
After approved installation of OT16F3, check positive isolation and door operation. Use only documented safe test methods and include connected equipment behavior.
Record the OT16F3 as-left results, asset tag, revision, date and witness. Restore alarms, interlocks and normal control before service handover.
What changes at installation?
Installing OT16F3 may affect adjacent wiring, panel access and auxiliary accessories. Check clearance and isolate the correct energy sources under the site's permit system.
Before disturbing OT16F3, save photos, configuration, parameter values and an alarm baseline. Keep removed parts identifiable until acceptance is signed.
What should purchasing retain?
The ABB OT16F3 record should include the complete designation, required accessories, label evidence and the current installation manual revision.
For any proposed substitute to OT16F3, obtain written confirmation of every changed technical characteristic and the site's acceptance.
Other codes in this same series
The following OT16F3 references can accompany an ABB OT16F3 enquiry. Suffix changes can affect ratings, fit or approvals, so none is an automatic replacement.
No other unassigned OT16F3 reference is grouped with OT16F3 in this release.
Enquiry and acceptance handoff
Quote ABB OT16F3 exactly, include the asset tag and duty, and request confirmation of any missing accessories or alternative build.
Keep the approved OT16F3 comparison, installation checks and test results in the maintenance record.
ABB OT1 visually similar order-code references
These strings are collected by their similar printed ordering-code format. They may identify different device types, electrical ratings or accessories. Listing them together does not mean they share a product series, function, approval or interchangeability. Confirm the exact ABB designation and manufacturer documentation before ordering or substitution.
OT100U0 references
- OT100U03P
OT1250E references
- OT1250E03 1SCA022860R5510
- OT1250E12
- OT1250E12- 1SCA101552R1001
OT1600E references
- OT1600E11, 1SCA113106R1001
OT160E0 references
- OT160E03CP
OT160EV references
- OT160EV033
OT16F3 references
- OT16F3