BASIC INFO

Technical fit record for ABB DCS800-S01-0900-05+L508+S174 (3ADT218435R001)

ABB DCS800-S01-0900-05+L508+S174 (3ADT218435R001) is indexed here as a specific buying and service reference. Confirm its complete designation before assuming that another family member has the same terminals, electrical duty or approvals.

Verified technical data

Technical itemVerified value / selection note
Complete designationDCS800-S01-0900-05+L508+S174 (3ADT218435R001)
Product familyDCS800-S01-0900-05
Component roleDCS800 industrial DC drive configuration
FamilyDCS800-S01 DC drive
Base designation0900-05
Options+L508 and +S174; verify engineered build
Order reference3ADT218435R001; confirm complete unit record
RatingsDo not infer from suffix without full nameplate
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

The table for ABB DCS800-S01-0900-05+L508+S174 (3ADT218435R001) separates verified family data from the configuration checks that still require a nameplate or ABB order record. Do not use a family rating as an unconditional guarantee for the installed unit.

Interface checklist

Before ordering DCS800-S01-0900-05+L508+S174 (3ADT218435R001), compare the installed terminal or connector arrangement, power source, mounting envelope and ancillary hardware with the current drawing.

Document the serial number and revision of DCS800-S01-0900-05+L508+S174 (3ADT218435R001) where available. If a supplier proposes a substitute, obtain engineering acceptance for every changed interface.

Purchase decision

Specify ABB DCS800-S01-0900-05+L508+S174 (3ADT218435R001) against a particular asset tag and duty. This unit is used to regulate the engineered DC motor system; record the intended circuit, process or equipment location before requesting a quote.

For DCS800-S01-0900-05+L508+S174 (3ADT218435R001), confirm armature and field ratings, option cards, mains, cooling and motor parameters. A matching short family name is not sufficient evidence of electrical, mechanical or software interchangeability.

Receipt inspection

On arrival, compare the supplied DCS800-S01-0900-05+L508+S174 (3ADT218435R001) label and order code with the approved purchase description. Inspect packaging, terminals, seals and visible damage.

Do not install DCS800-S01-0900-05+L508+S174 (3ADT218435R001) when the shipped suffix, control voltage, release or approval differs from the approved build; resolve that discrepancy before commissioning.

Site preparation

Plan the DCS800-S01-0900-05+L508+S174 (3ADT218435R001) replacement under the facility isolation and permit rules. Preserve photographs, configuration files, settings and a diagnostic baseline before disturbing wiring.

Check enclosure temperature, grounding, segregation and protection coordination for DCS800-S01-0900-05+L508+S174 (3ADT218435R001). Record any accessory that is supplied separately rather than assuming it is in the device box.

Lifecycle handover

Keep ABB DCS800-S01-0900-05+L508+S174 (3ADT218435R001) linked to its exact spares description, drawings and current manual revision. This helps the next maintenance team identify the same configuration rather than a superficially similar item.

Review the first operating period of DCS800-S01-0900-05+L508+S174 (3ADT218435R001) for alarms, heating, drift or switching anomalies and update the asset record if the installed build differs from the original request.

Commissioning evidence

For DCS800-S01-0900-05+L508+S174 (3ADT218435R001), check speed, field supervision, current and protective trips. Carry out only the tests approved for this device and the connected installation.

Save the as-left settings, measured results, witness and work-order reference for DCS800-S01-0900-05+L508+S174 (3ADT218435R001). Any temporary bypass or inhibited alarm must be removed before normal operation.

Related configuration references

The following DCS800-S01-0900-05 codes are recorded with ABB DCS800-S01-0900-05+L508+S174 (3ADT218435R001) for enquiry. Suffixes may alter ratings, dimensions, approvals or accessories; these are not automatic replacements.

  • DCS800-S01-0900-05+L508+S174 CH

Information to send with an enquiry

Quote ABB DCS800-S01-0900-05+L508+S174 (3ADT218435R001) exactly and include the asset tag, electrical or process duty, required accessories and delivery documentation.

For DCS800-S01-0900-05+L508+S174 (3ADT218435R001), request written confirmation of any deviation from the fitted unit before accepting an alternative.

 

 

Pre:ABB CA4-22M 1SBN010140R1122 Front-Mounted Auxiliary Contact Block | Verified Selection and Purchasing Notes Next:ABB EF370-380 Electronic Motor Overload Relay — Ratings, Connections and Acceptance