ABB 1SVR405669R0000 acceptance profile
ABB 1SVR405669R0000 names the exact universal-relay socket holder used in this service profile. Its job is to retain the approved CR-U relay. The category image is a reference image, not proof that the delivered ABB 1SVR405669R0000 has the same physical configuration.
Technical data for the order code
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 1SVR405669R0000 |
| Product family | CR-UH universal relay holders |
| Component role | universal-relay socket holder |
| Exact ABB order reference | 1SVR405669R0000 |
| ABB product series | CR-UH universal relay holders |
| ABB order code | 1SVR405669R0000 |
| Manufacturer designation | CR-UH |
| Manufacturer product text | The CR-UH holder is from the the CR-U (universal) relay range. This metal holder is suitable for all CR-U sockets. CR-UH |
| ABB designation | CR-UH |
| Host | CR-U sockets in ABB description |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
Read the ABB 1SVR405669R0000 designation alongside the installed-equipment documentation. A difference in host, frame, connector, rating or kit contents can change whether ABB 1SVR405669R0000 is suitable.
Record the current assembly
Find the existing ABB 1SVR405669R0000 position on the drawing and take a legible photograph of the installed marking. Record the host model, serial or frame identifier and revision.
For ABB 1SVR405669R0000, capture the wiring, mounting orientation and any parameter image before removing the existing component.
Compare the supply item
Compare the delivered ABB 1SVR405669R0000 label and package with the approved order. Check CR-U socket type and CR-UH holder geometry before work begins.
If another ABB 1SVR405669R0000 configuration is proposed, have the design owner review its technical identity; similarity of appearance does not establish equivalence.
Plan the isolation
Before handling ABB 1SVR405669R0000, identify every relevant electrical and mechanical energy source. Apply the approved lockout and stored-energy discharge procedure.
Keep ABB 1SVR405669R0000 installation instructions available at the work point. Observe the host manufacturer's limits for connection, torque, clearance and protective covers.
Fit and inspect
Install ABB 1SVR405669R0000 in the documented location without forcing plugs, shafts or terminals. Check that labels remain readable and routing matches the original drawing.
Inspect ABB 1SVR405669R0000 fasteners, strain relief, insulation, barriers and intended movement as relevant to this specific component.
Functional evidence
With the assembly made safe for an authorized test, verify relay retention without socket damage. Include the relevant alternate state or alarm condition for ABB 1SVR405669R0000.
Record the ABB 1SVR405669R0000 test steps, observed results and any deviations. Do not close the maintenance record on an unverified function.
Return-to-service decision
Compare ABB 1SVR405669R0000 behavior against the approved acceptance criteria. Review protection, cooling, communication or relay response as appropriate to the role.
Only return equipment to service when ABB 1SVR405669R0000 identification, installation and functional results have been signed off.
Keep the spare record usable
Store the complete ABB 1SVR405669R0000 order code with the supported host and the tested configuration. Keep replacement and commissioning records with the asset.
When requesting ABB 1SVR405669R0000 again, include the full designation and known variant restrictions rather than a short family label.
Service handover
State the accepted ABB 1SVR405669R0000 code in the final maintenance and procurement record.
Retain the ABB 1SVR405669R0000 test evidence for the next service intervention.
ABB 1SVR visually similar order-code references
These strings are collected by their similar printed ordering-code format. They may identify different device types, electrical ratings or accessories. Listing them together does not mean they share a product series, function, approval or interchangeability. Confirm the exact ABB designation and manufacturer documentation before ordering or substitution.
1SVR 01 references
- 1SVR 011 732 R1300
1SVR011 references
- 1SVR011700R0000
- 1SVR011708R0400
- 1SVR011715R1200
- 1SVR011782R0700
1SVR040 references
- 1SVR040000R1700
- 1SVR040006R0100
- 1SVR040009R1400
1SVR320 references
- 1SVR320561R1000 CP-S.1 24/5.0
- 1SVR320861R1000 CP-S.1 24/40.0
1SVR360 references
- 1SVR360563R1001
- 1SVR360663R1001
- 1SVR360663R1001 CP-C.1 24/10.0
- 1SVR360763R1001
1SVR405 references
- 1SVR405600R1000
- 1SVR405601R0000
- 1SVR405601R1000
- 1SVR405601R1010
- 1SVR405601R3000
- 1SVR405601R3000 CR-P230AC2
- 1SVR405601R4000
- 1SVR405601R8000
- 1SVR405611R1000
- 1SVR405611R1100
- 1SVR405612R1000
- 1SVR405612R3000
- 1SVR405612R7100
- 1SVR405613R1000
- 1SVR405613R1100
- 1SVR405613R3000
- 1SVR405613R3100
- 1SVR405613R8000
- 1SVR405613R8100
- 1SVR405613R8300
- 1SVR405622R3000
- 1SVR405650R0000
- 1SVR405650R0100
- 1SVR405650R1000
- 1SVR405651R1100
- 1SVR405651R2100
- 1SVR405651R3000
- 1SVR405651R3100
- 1SVR405651R3300
- 1SVR405653R1000
- 1SVR405654R1000
- 1SVR405655R0000
- 1SVR405655R0100
- 1SVR405655R1000
- 1SVR405658R0000
- 1SVR405659R0000
- 1SVR405659R1000
- 1SVR405659R1100
- 1SVR405660R0000
- 1SVR405667R0000
- 1SVR405669R0000
- 1SVR405670R0000
1SVR427 references
- 1SVR427024R0000
- 1SVR427025R0000 CP-C-24/10.0
- 1SVR427026R0000
- 1SVR427026R0000 CP-C 24/20.0
- 1SVR427030R0000
- 1SVR427031R0000
- 1SVR427032R0000
- 1SVR427034R0000
- 1SVR427035R0000
- 1SVR427036R0000
- 1SVR427043R0100
- 1SVR427043R1200
- 1SVR427045R0400
- 1SVR427060R0300
1SVR430 references
- 1SVR430213R0200
- 1SVR430711R1300
- 1SVR430720R0400
- 1SVR430750R0400
- 1SVR430794R3300
- 1SVR430800R9100
- 1SVR430811R1300
1SVR440 references
- 1SVR440713R0300
- 1SVR440799R6100
1SVR450 references
- 1SVR450081R0000
- 1SVR450091R0000
- 1SVR450116R5000
- 1SVR450116R5100
- 1SVR450117R1300
1SVR470 references
- 1SVR470670R1000
1SVR500 references
- 1SVR500020R0000
- 1SVR500020R1100
- 1SVR500100R0000
- 1SVR500100R0100
- 1SVR500110R0000
- 1SVR500160R0000
- 1SVR500211R0100
1SVR508 references
- 1SVR508020R0000
- 1SVR508100R0000
- 1SVR508100R0000 CT-ERC.12
1SVR550 references
- 1SVR550029R8100
- 1SVR550100R1100
- 1SVR550100R5100
- 1SVR550107R1100
- 1SVR550107R2100
- 1SVR550107R4100
- 1SVR550107R5100
- 1SVR550118R1100
- 1SVR550127R1100
- 1SVR550127R4100
- 1SVR550137R1100
- 1SVR550217R4100
- 1SVR550801R9300
- 1SVR550851R9500
- 1SVR550870R9400
- 1SVR550881R9400
1SVR560 references
- 1SVR560731R3701,CM-UFD.M31M
1SVR630 references
- 1SVR630020R3100
- 1SVR630885R3300
1SVR730 references
- 1SVR730010R0200
- 1SVR730010R0200,CT-MFS.21S,multifunction,2c/o,24-240VAC
- 1SVR730020R0200
- 1SVR730040R3300
- 1SVR730100R0300
- 1SVR730100R3100
- 1SVR730120R3100
- 1SVR730180R3300
- 1SVR730670R0200
- 1SVR730700R2200
- 1SVR730712R1200
- 1SVR730712R1300
- 1SVR730712R2200
- 1SVR730720R1400
- 1SVR730740R0300
- 1SVR730750R0400
- 1SVR730750R0400 (CM-EFS.2S)
- 1SVR730774R3300
- 1SVR730784R2300
- 1SVR730794R3300
- 1SVR730794R3300 CM-PVS
- 1SVR730794R3300 CM-PVS.41S
- 1SVR730824R9300
- 1SVR730824R9300, CM-PFS.S
- 1SVR730830R0400
- 1SVR730830R0500
- 1SVR730840R0500
- 1SVR730840R0500 CM-SRS.22S
- 1SVR730840R0500(CM-SRS.22S)
- 1SVR730840R0700
- 1SVR730841R0300
- 1SVR730850R0200
- 1SVR730884R3300
- 1SVR730884R3300 CM-MPS.41S
- 1SVR730884R4300
- 1SVR730885R3300
- 1SVR730885R3300, CM-MPS.21S
- 1SVR730885R4300
1SVR740 references
- 1SVR740824R9300
1SVR750 references
- 1SVR750489R8300