ABB 1SAM340000R1001 application and verification guide
Use the following decision gates to specify ABB 1SAM340000R1001 for an existing installation and to accept the delivered unit against the engineering record.
Key technical parameters
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 1SAM340000R1001 |
| Product family | MS132-0.16T |
| Component role | 0.10–0.16 A primary transformer protection breaker |
| Complete order code | 1SAM340000R1001 |
| ABB product series | MS132-0.16T |
| Setting range | 0.10–0.16 A |
| Application | Control-transformer primary |
| Magnetic threshold | High inrush-tolerant transformer version |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The values for ABB 1SAM340000R1001 derive from the linked ABB product information. Check the delivered label and application-specific limits before use.
Gate 2 — electrical interface
Check the ABB 1SAM340000R1001 current, voltage and contact or I/O arrangement against the installed circuit. Trace every supply and feedback conductor, then note required auxiliary devices or overload protection.
For ABB 1SAM340000R1001, verify transformer inrush, primary current and coordination. Do not infer a replacement from a photograph or a broad product-family claim.
Gate 1 — identity and duty
ABB 1SAM340000R1001 is intended to protect the specified control-transformer primary. Obtain the full article code from the device or approved drawing before placing the order; the series name alone does not define its rating or options.
Compare ABB 1SAM340000R1001 with the original circuit duty, switching frequency, fault level and environmental conditions. An adjacent number in the series can be a different electrical part even when the housing looks alike.
Gate 4 — settings and coordination
Record every relevant ABB 1SAM340000R1001 current dial, trip class, reset mode, control supply or fieldbus setting. Compare them with the approved protection study rather than copying a nearby machine's settings.
Where ABB 1SAM340000R1001 is magnetic-only, provide the separately designed overload function. Where it is a controller, retain the configuration and network files needed for restoration.
Gate 3 — mechanical interface
Review ABB 1SAM340000R1001 mounting width, terminal access, cable bend space and enclosure clearance before the shutdown. A different generation may reposition connectors or change accessories.
Keep the ABB 1SAM340000R1001 host equipment and wiring diagram in the work pack. If the original assembly has add-on blocks or busbar links, confirm their compatibility separately.
Gate 5 — acceptance test
After qualified personnel install ABB 1SAM340000R1001, check isolation and protected start-up. Capture the test method, actual results and any revised settings in the commissioning record.
For ABB 1SAM340000R1001, check the normal state, commanded change and fault or off-state as applicable. Return the circuit to service only after the assembled function is accepted.
Gate 6 — spare governance
Archive the ABB 1SAM340000R1001 label photo, manufacturer document and as-left record with the asset. If the unit later becomes unavailable, request a written successor comparison rather than silently changing the order code.
The ABB 1SAM340000R1001 page is a purchasing reference for the exact marked article. Same-series alternatives are grouped below only as enquiry references; their settings and interfaces still need individual checking.
Other order codes in this series
These designations are listed under ABB 1SAM340000R1001 as related same-series variants. They may differ in current, supply, contacts or equipment generation, and are not presumed interchangeable. A code included here is not assigned a separate product page.
- 1SAM340000R1004
- 1SAM340000R1005
- 1SAM340000R1007
- 1SAM340000R1008
- 1SAM340000R1009
- 1SAM340000R1010
- 1SAM340000R1011
- 1SAM340000R1012
- 1SAM340000R1013
- 1SAM340000R1014
Release and handover
Before buying ABB 1SAM340000R1001, confirm exact marking, interfaces and approved settings with the site engineer.
After fitting ABB 1SAM340000R1001, save the test evidence and update the equipment spare record.