ABB MS116-0.4 1SAM250000R1003 | Motor-Control Specification and Duty Review

description:Technical identification and selection guidance for ABB 1SAM250000R1003, including verified family data, system compatibility and configuration checks....
BASIC INFO

Evaluating ABB 1SAM250000R1003 for the existing panel

Use the following decision gates to specify ABB 1SAM250000R1003 for an existing installation and to accept the delivered unit against the engineering record.

Key technical parameters

Technical itemVerified value / selection note
Complete designation1SAM250000R1003
Product familyMS116-0.4
Component role0.25–0.4 A manual motor starter
Complete order code1SAM250000R1003
ABB product seriesMS116-0.4
Setting range0.25–0.4 A
Trip class10A
Width45 mm
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

The values for ABB 1SAM250000R1003 derive from the linked ABB product information. Check the delivered label and application-specific limits before use.

Gate 1 — identity and duty

ABB 1SAM250000R1003 is intended to switch and protect a small motor without a fuse. Obtain the full article code from the device or approved drawing before placing the order; the series name alone does not define its rating or options.

Compare ABB 1SAM250000R1003 with the original circuit duty, switching frequency, fault level and environmental conditions. An adjacent number in the series can be a different electrical part even when the housing looks alike.

Gate 3 — mechanical interface

Review ABB 1SAM250000R1003 mounting width, terminal access, cable bend space and enclosure clearance before the shutdown. A different generation may reposition connectors or change accessories.

Keep the ABB 1SAM250000R1003 host equipment and wiring diagram in the work pack. If the original assembly has add-on blocks or busbar links, confirm their compatibility separately.

Gate 2 — electrical interface

Check the ABB 1SAM250000R1003 current, voltage and contact or I/O arrangement against the installed circuit. Trace every supply and feedback conductor, then note required auxiliary devices or overload protection.

For ABB 1SAM250000R1003, verify nameplate current, setting dial, phase duty and breaking capacity. Do not infer a replacement from a photograph or a broad product-family claim.

Gate 4 — settings and coordination

Record every relevant ABB 1SAM250000R1003 current dial, trip class, reset mode, control supply or fieldbus setting. Compare them with the approved protection study rather than copying a nearby machine's settings.

Where ABB 1SAM250000R1003 is magnetic-only, provide the separately designed overload function. Where it is a controller, retain the configuration and network files needed for restoration.

Gate 6 — spare governance

Archive the ABB 1SAM250000R1003 label photo, manufacturer document and as-left record with the asset. If the unit later becomes unavailable, request a written successor comparison rather than silently changing the order code.

The ABB 1SAM250000R1003 page is a purchasing reference for the exact marked article. Same-series alternatives are grouped below only as enquiry references; their settings and interfaces still need individual checking.

Gate 5 — acceptance test

After qualified personnel install ABB 1SAM250000R1003, verify current setting and trip response. Capture the test method, actual results and any revised settings in the commissioning record.

For ABB 1SAM250000R1003, check the normal state, commanded change and fault or off-state as applicable. Return the circuit to service only after the assembled function is accepted.

Other order codes in this series

These designations are listed under ABB 1SAM250000R1003 as related same-series variants. They may differ in current, supply, contacts or equipment generation, and are not presumed interchangeable. A code included here is not assigned a separate product page.

  • 1SAM250000R1004
  • 1SAM250000R1005
  • 1SAM250000R1006
  • 1SAM250000R1007
  • 1SAM250000R1008
  • 1SAM250000R1010
  • 1SAM250000R1011
  • 1SAM250000R1012
  • 1SAM250000R1013
  • 1SAM250000R1015

Release and handover

Before buying ABB 1SAM250000R1003, confirm exact marking, interfaces and approved settings with the site engineer.

After fitting ABB 1SAM250000R1003, save the test evidence and update the equipment spare record.

 

 

Pre:ABB MO325-9 1SAM160000R1010 | Replacement Interface and Test Checklist Next:ABB 1SAM340000R1001 MS132-0.16T: Exact Order Code, Ratings and Commissioning