Schneider Electric LVR05500A40T order identity and use limits

Use the complete phrase LVR05500A40T for this PowerLogic PFC detuned reactor when requesting a quotation. The category main image is a shared reference picture, not proof of the exact LVR05500A40T variant or its as-installed option.

Key technical specifications

Technical itemVerified value / selection note
Model / requested phraseLVR05500A40T
Product identityPowerLogic PFC detuned reactor
Compensation reference50 kvar
Tuning210 Hz, 5.7%
System400 V, 50 Hz
PurposeAnti-harmonic detuned reactor

Fit and installation

For LVR05500A40T, identify the actual host assembly and site duty. Compare voltage, current, contacts, communication, mechanical mounting or other applicable interfaces against the installed item. Review harmonic study and capacitor-bank matching. A generic picture cannot establish compatibility for LVR05500A40T.

Supplier enquiry

The buyer should copy LVR05500A40T exactly, then request manufacturer data, quantity, delivery region, revision and included accessories. If the supplier offers a different string instead of LVR05500A40T, ask for a written cross-reference and engineering approval before purchase.

Receiving check

When LVR05500A40T arrives, compare the printed marking with the approved order and retain a label photograph. Check package condition, terminals and accessories. Record the final installation location and the functional or commissioning test of LVR05500A40T.

Decision notes

A purchase decision for LVR05500A40T should be based on the exact current datasheet and the site's electrical or control design. Family-level ratings are not automatically the rating of a particular LVR05500A40T; verify any regional or suffix-dependent value before energising equipment.

Keep a record of why LVR05500A40T was selected, especially when it is used as a spare. This helps the next buyer distinguish LVR05500A40T from neighboring codes that look alike but may perform a different role.

Visually similar codes in this catalogue

The 2 strings below resemble the LVR code pattern and are indexed on representative LVR05500A40T for search. They are not claimed to have the same function, rating or approvals as LVR05500A40T; review each full code separately.

LVR07250A40T
LVR07500A40T

Purchase record

Specify LVR05500A40T with its destination, application and required documents. Confirm the delivered LVR05500A40T marking and record the acceptance result. Any change from LVR05500A40T should be approved against the actual duty, not the appearance of the category picture.

 

 

Pre:Purchasing Schneider KTB0630DC5 Canalis KT circuit-breaker tap-off unit for Industrial Service Next:Schneider Electric LX4D8MD TeSys Deca contactor coil | Technical Specification and Fit Guide