GV7RE100 Schneider Electric TeSys GV7 motor circuit breaker | Site Engineering and Procurement Notes

description:Schneider Electric GV7RE100 TeSys GV7 motor circuit breaker: key ratings, application and service notes, related references....
BASIC INFO

GV7RE100 field application brief for TeSys GV7 motor circuit breaker

GV7RE100 is a precise Schneider Electric ordering reference for TeSys GV7 motor circuit breaker. The shared main collage is a category reference image rather than an exact configuration photo. The verified GV7RE100 values below should be combined with site-specific engineering checks.

Verified technical data

Technical itemVerified value / selection note
Full ordering codeGV7RE100
Product identityTeSys GV7 motor circuit breaker
Poles3
Current setting60–100 A
ProtectionThermal-magnetic, AC-3 application

Selection point

The main field decision for GV7RE100 is: Set protection to the motor nameplate and check starter coordination. A visually close catalog number must be compared with the full GV7RE100 specification, not accepted by prefix alone.

Risk and action record

Identity risk: Using an abbreviated GV7RE100 code can hide a different option, rating or connector. Capture the entire nameplate.

Application risk: Using GV7RE100 without checking the actual circuit can change the protection, signal or control behavior.

Fit action: Compare GV7RE100 terminals, mounting and accessories to the approved drawing and the manufacturer's current instructions.

Acceptance action: Record the delivered GV7RE100 code, settings and functional test result before handing the equipment back.

Order and delivery checks

The purchase order for GV7RE100 should include the complete code, quantity, destination, equipment tag and any separate terminal, base or accessory parts. Check the supplied GV7RE100 against the exact ordered designation when it arrives.

Review current regional availability for GV7RE100, especially for legacy equipment. A proposed replacement of GV7RE100 may call for different wiring, controls or protection settings; document and approve those changes before installation.

Commissioning note

Isolate the relevant equipment before working on GV7RE100. Preserve existing wiring labels and software or parameter backups where appropriate. After installing GV7RE100, test the approved function and file the result with the delivered nameplate.

Close-looking model index

The 2 codes below resemble GV7RE100 in the visible GV7 pattern. They are grouped here instead of receiving their own pages. They are references for search, not claims that any code can replace GV7RE100 without technical review.

GV7AB11
GV7RE80

Final decision record

Approve GV7RE100 only after the exact code, verified data, site fit, accessories and commissioning plan have been checked. Save the GV7RE100 evidence so future service personnel can distinguish a true repeat order from a merely similar-looking device.

 

 