C12H3TM160L technical identity for site engineers and buyers
C12H3TM160L is a precise Schneider Electric ordering reference for ComPacT NSXm160H circuit breaker. The shared main collage is a category reference image rather than an exact configuration photo. The verified C12H3TM160L values below should be combined with site-specific engineering checks.
Verified technical data
| Technical item | Verified value / selection note |
|---|---|
| Full ordering code | C12H3TM160L |
| Product identity | ComPacT NSXm160H circuit breaker |
| Poles / trip | 3P3D, TMD |
| Rated current | 160 A |
| Breaking capacity | 70 kA at 415 V AC |
Selection point
The main field decision for C12H3TM160L is: Verify fault level, trip coordination and EverLink termination. A visually close catalog number must be compared with the full C12H3TM160L specification, not accepted by prefix alone.
Risk and action record
Identity risk: Using an abbreviated C12H3TM160L code can hide a different option, rating or connector. Capture the entire nameplate.
Application risk: Using C12H3TM160L without checking the actual circuit can change the protection, signal or control behavior.
Fit action: Compare C12H3TM160L terminals, mounting and accessories to the approved drawing and the manufacturer's current instructions.
Acceptance action: Record the delivered C12H3TM160L code, settings and functional test result before handing the equipment back.
Order and delivery checks
The purchase order for C12H3TM160L should include the complete code, quantity, destination, equipment tag and any separate terminal, base or accessory parts. Check the supplied C12H3TM160L against the exact ordered designation when it arrives.
Review current regional availability for C12H3TM160L, especially for legacy equipment. A proposed replacement of C12H3TM160L may call for different wiring, controls or protection settings; document and approve those changes before installation.
Commissioning note
Isolate the relevant equipment before working on C12H3TM160L. Preserve existing wiring labels and software or parameter backups where appropriate. After installing C12H3TM160L, test the approved function and file the result with the delivered nameplate.
Close-looking model index
The 6 codes below resemble C12H3TM160L in the visible C12 pattern. They are grouped here instead of receiving their own pages. They are references for search, not claims that any code can replace C12H3TM160L without technical review.
Final decision record
Approve C12H3TM160L only after the exact code, verified data, site fit, accessories and commissioning plan have been checked. Save the C12H3TM160L evidence so future service personnel can distinguish a true repeat order from a merely similar-looking device.