Schneider C10F3: ratings, interface and order decision
Use this C10F3 brief to identify the Schneider Electric ComPacT NSX100F circuit-breaker frame, compare verified catalog characteristics and define what must be checked at the site. The shared collage is a category reference image; it does not depict the exact C10F3 configuration.
Key technical data
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | C10F3 |
| Product family | ComPacT NSX100F circuit-breaker frame |
| Frame current | 100 A |
| Poles | Three |
| Breaking capacity | 36 kA at 415 V AC class |
Buyer question: what must match?
Start with the complete C10F3 code, not only a family name. Compare the fitted item's nameplate with the proposed C10F3 supply, rating, terminals, mounting and accessories. A close-looking suffix can change the electrical or mechanical interface.
For C10F3, document the actual panel or machine duty and any associated drawing. A frame requires a separately selected compatible trip unit. When the application is safety-related, have a qualified engineer assess the complete function and applicable design requirements.
At the equipment
Photograph the existing C10F3 installation before removal. Record the cable labels, environmental exposure, protective devices and available clearance. If C10F3 is part of an automation assembly, back up relevant settings and record the matching controller, drive or accessory revision.
Do not infer drop-in interchangeability from the image or the C10F3 family description. Confirm the current manufacturer data and installation manual for the exact C10F3 variant; compare the delivered nameplate before work begins.
Order and commissioning notes
The purchasing request for C10F3 should state the full code, quantity, required accessories and the intended equipment tag. For legacy equipment, confirm regional availability and lifecycle status rather than assuming that a historically used C10F3 remains the preferred replacement.
After qualified personnel install C10F3 under site isolation procedures, check wiring, settings and functional response against the approved drawing. Keep the test record with the C10F3 designation for subsequent service.
Related-looking model codes
These 94 C10-pattern codes resemble C10F3 and are indexed on this representative page instead of receiving separate pages in this publishing set. They are not declared equivalent to C10F3; verify every complete code and option string.
Release decision
Release the C10F3 order only after the exact rating, matching accessories and fit are confirmed. Retain the C10F3 data record and commissioning evidence so future maintenance can distinguish this exact variant from adjacent codes.