Working with 56105 RH10M Vigirex RH10M residual-current relay in an installed system

This page records the full designation 56105 RH10M for procurement and maintenance. The category main image is reused as a reference illustration and may not depict the exact 56105 RH10M unit. Use the technical items below with the current manufacturer documentation and the actual site design.

Technical data at a glance

Technical itemVerified value / selection note
Complete designation56105 RH10M
Product identityVigirex RH10M residual-current relay
Manufacturer reference56105
Sensitivity300 mA
Supply12/24 V AC or 12/48 V DC listing
MountingDIN rail

2. Check the technical interface

Compare 56105 RH10M against the host equipment, mounting dimensions, terminals and necessary accessories. Check electrical ratings and interface protocols where they apply. A similar-looking code can change a critical attribute, so the full 56105 RH10M designation must remain on the review sheet.

3. Request and assess a quotation

Ask the supplier to quote 56105 RH10M exactly, with quantity, destination and current manufacturer documents. Confirm whether the offer includes every needed accessory. If 56105 RH10M is unavailable, demand a written replacement proposal and review every affected parameter before approving it.

4. Receive and inspect

When 56105 RH10M arrives, compare the nameplate or package label to the approved order. Photograph the marking, inspect physical condition and account for supplied parts. Do not place an item marked differently from 56105 RH10M into service without an approved substitution record.

5. Install and verify

Follow the safe-isolation and installation instructions applicable to 56105 RH10M. Verify wiring, mounting, configuration and protective settings against the project design. Record the functional or commissioning test and the final installed 56105 RH10M identifier.

1. Define the installed duty

Before selecting 56105 RH10M, identify the equipment tag, supply, load and operating conditions. The intended role is Vigirex RH10M residual-current relay. Select the toroid and protective action for the site. Record any environmental or safety requirement that will affect the final specification of 56105 RH10M.

Why the complete code matters

The confirmed details in the table are deliberately limited to information supported by manufacturer material for 56105 RH10M. Additional values may depend on a suffix, revision, regional approval or mating component. Before ordering or energising 56105 RH10M, verify any unsupplied value in the current exact-product document.

Keep 56105 RH10M visible in the bill of materials, quotation and maintenance log. This reduces the chance that a near-looking part is selected by appearance alone. The shared image on this page does not establish the physical identity or ratings of 56105 RH10M.

Similar-looking designations indexed here

There is no additional unassigned 56105-pattern designation grouped with 56105 RH10M in this catalogue. Any proposed alternate remains subject to its own technical review.

Close-out record

After acceptance, retain the final 56105 RH10M designation, the approved data sheet, supplier details and commissioning result. If the installed part differs from 56105 RH10M, document the engineering approval and update the maintenance record.

 

 

Pre:Schneider INS63 3P 28902 ComPacT INS switch-disconnector Product Specification for Site Review Next:Schneider Electric 56170 / RH99M VigiPacT RH99M residual-current relay | Technical Data and Lifecycle Guide