Schneider Electric 48514 MasterPact NW second MX opening release | Technical Identity and Ordering Checks

description:Schneider Electric 48514 MasterPact NW second MX opening release: key ratings, application and service notes, related references....
BASIC INFO

Schneider 48514 | identification and field-fit notes for MasterPact NW second MX opening release

48514 is a Schneider Electric reference for MasterPact NW second MX opening release. The shared main image illustrates the relevant category, not the exact 48514 item. The full manufacturer code should be the purchasing and receiving reference; visual similarity alone is not a compatibility test.

Verified technical record

Technical itemVerified value / selection note
Exact reference48514
ManufacturerSchneider Electric
Product identityMasterPact NW second MX opening release
Mounting contextDrawout MasterPact NW
ReleaseSecond MX opening release
Supply200 to 250 V AC/DC per listing

What to verify before ordering

Start with the installed nameplate or packaged label for 48514. Record the complete code, quantity, location and equipment revision. For 48514, check the electrical and mechanical ratings shown in the verified record, then compare them to the actual circuit duty and the applicable manufacturer installation instructions.

Purchasing checkpoint
Request the exact reference, manufacturer documentation, accessory list, lifecycle/stock status and a written statement of any substitution.

A quotation for 48514 should distinguish a new original component from a surplus or repaired unit. Ask for the exact 48514 marking on the offered product. Where an older reference is no longer marketed, an alleged successor requires an explicit fit and protection review before approval.

Physical and electrical fit

Confirm the enclosure, rail or panel mounting, terminal access and available clearances for 48514. A number on a list does not establish terminal orientation, pole arrangement, wire size, fuse type, or trip-unit pairing. Verify the exact configuration of 48514 against the existing assembly, not against a nearby catalogue number.

For switching and protection items, check voltage, current, breaking or sensing duty and coordination with upstream and downstream equipment. For the metering and control versions of 48514, confirm sensor, wiring, supply and output details. Only the properties stated in the table above are treated as documented for 48514; any unlisted value remains to be checked.

Receiving and commissioning sequence

  1. Match the delivered designation with the purchase order and inspect packaging.
  2. Confirm documented ratings and the intended installation point.
  3. Install under the site isolation procedure and manufacturer instructions.
  4. Record the acceptance test, settings and final equipment tag.

Before fitting 48514, preserve settings, drawings and photographs of the original arrangement where relevant. Commissioning should test the actual function of 48514 in its installed context. A part that looks correct may still have a different rating, contact state, release voltage or protection characteristic.

Similar-looking catalogue references

The following 4 source-list codes share the visible 485 prefix with 48514. They are grouped for search and enquiry only. They may serve different functions and are not claimed to be interchangeable with 48514; check every complete code separately.

48504
48527
48535
48536

Decision note

Release 48514 for purchase only after the code, documented identity, installation duty and supplier offer agree. Keep 48514 in the order and acceptance record. Any proposed substitute should be evaluated separately rather than silently changing the reference.

 

 

Pre:How to Specify Schneider 48070 MasterPact NW25H1 circuit-breaker frame for an Existing Installation Next:50437 Schneider Vigirex closed toroid for residual-current protection | Verified Data, Fit and Acceptance Guide