24239 Multi 9 C60N miniature circuit breaker: verified reference and application checks

24239 is a Schneider Electric reference for Multi 9 C60N miniature circuit breaker. The shared main image illustrates the relevant category, not the exact 24239 item. The full manufacturer code should be the purchasing and receiving reference; visual similarity alone is not a compatibility test.

Verified technical record

Technical itemVerified value / selection note
Exact reference24239
ManufacturerSchneider Electric
Product identityMulti 9 C60N miniature circuit breaker
Poles1
Rated current6 A
Trip curveC

What to verify before ordering

Start with the installed nameplate or packaged label for 24239. Record the complete code, quantity, location and equipment revision. For 24239, check the electrical and mechanical ratings shown in the verified record, then compare them to the actual circuit duty and the applicable manufacturer installation instructions.

Purchasing checkpoint
Request the exact reference, manufacturer documentation, accessory list, lifecycle/stock status and a written statement of any substitution.

A quotation for 24239 should distinguish a new original component from a surplus or repaired unit. Ask for the exact 24239 marking on the offered product. Where an older reference is no longer marketed, an alleged successor requires an explicit fit and protection review before approval.

Physical and electrical fit

Confirm the enclosure, rail or panel mounting, terminal access and available clearances for 24239. A number on a list does not establish terminal orientation, pole arrangement, wire size, fuse type, or trip-unit pairing. Verify the exact configuration of 24239 against the existing assembly, not against a nearby catalogue number.

For switching and protection items, check voltage, current, breaking or sensing duty and coordination with upstream and downstream equipment. For the metering and control versions of 24239, confirm sensor, wiring, supply and output details. Only the properties stated in the table above are treated as documented for 24239; any unlisted value remains to be checked.

Receiving and commissioning sequence

  1. Match the delivered designation with the purchase order and inspect packaging.
  2. Confirm documented ratings and the intended installation point.
  3. Install under the site isolation procedure and manufacturer instructions.
  4. Record the acceptance test, settings and final equipment tag.

Before fitting 24239, preserve settings, drawings and photographs of the original arrangement where relevant. Commissioning should test the actual function of 24239 in its installed context. A part that looks correct may still have a different rating, contact state, release voltage or protection characteristic.

Similar-looking catalogue references

No other currently unassigned 242-prefix catalogue number is placed with 24239. This does not imply that different suffixes are interchangeable.

Decision note

Release 24239 for purchase only after the code, documented identity, installation duty and supplier offer agree. Keep 24239 in the order and acceptance record. Any proposed substitute should be evaluated separately rather than silently changing the reference.

Other visually similar numeric references

These references have the visible 24 prefix and are included for search and enquiry. They are not claimed to share this product function, ratings or dimensions and are not interchangeable. Confirm the exact full designation and manufacturer documentation for each number.

24332
24333
24334
24335
24336
24340
24352
24395
24407
24581
24583
24599
24657
24658
24733

 

 