140ACO02000 analog-output module for a Modicon Quantum rack
The full 140ACO02000 reference matters because neighboring codes may change ratings or interfaces. This page gives a technical snapshot and a practical replacement checklist for 140ACO02000. The shared image represents the category, not the exact delivered 140ACO02000 unit.
Technical identity and ratings
| Technical item | Verified value / selection note |
|---|---|
| Complete reference | 140ACO02000 |
| Product family | Modicon Quantum analog output module |
| Channels | 4 analog outputs |
| Signal | 4–20 mA current output |
| Resolution | 12-bit class |
Selection decision
Check each output loop, load and signal scaling against the original control application. A current-output card cannot replace an analog input card merely because both use a Quantum rack.
For 140ACO02000, verify the actual supply, mating equipment and duty cycle. A family name is useful for search, but the complete 140ACO02000 suffix and installed configuration control the purchase decision.
Field checklist
- Record the old 140ACO02000 label, wiring and settings. Preserve the original project, channel assignments and terminal block. Schneider lists this reference as discontinued in several markets, so compare any proposed X80 migration at the system level.
- Compare the offered 140ACO02000 with the manufacturer's current technical description, accessories and lifecycle information. Test the installed function under the site's approved procedure.
Buyer questions
What should the order include?
Quote the exact 140ACO02000 designation, quantity, panel or machine identifier, supply and interface details. Attach a clear photo of the original label and the mating equipment.
Can a nearby model replace it?
Treat another code as a proposed alternative to 140ACO02000, not an automatic substitute. Compare electrical ratings, terminals, mechanical dimensions, certification and programming before approval.
How is the installation accepted?
For 140ACO02000, retain the as-found configuration, confirm the delivered reference and document a functional test. Where protection or safety is involved, use the applicable qualified validation process.
Similar designation references
The following 2 codes resemble 140ACO02000 and are grouped with this representative page. They need individual rating and function checks and are not asserted to be interchangeable with 140ACO02000.
140ACO02000C, 140ACO13000
Final order check
Confirm the printed 140ACO02000 code, current Schneider Electric or Clipsal documentation, the site's supply and environmental conditions, and the required accessories before committing to 140ACO02000. Keep this technical review with the purchase record for 140ACO02000.