TTH200-E1.H.BS temperature transmitter: sensor wiring and HART configuration
The ABB TTH200-E1.H.BS is a head-mounted temperature transmitter designation in ABB’s TTH200 family. ABB documents a universal sensor input for RTDs, thermocouples, resistance and millivolt signals, with a 4–20 mA HART output and 0.1% family accuracy reference. Actual loop configuration and approvals depend on the complete ordered suffix.
Key technical data
| Technical item | Verified value / selection note |
|---|---|
| Type designation | TTH200-E1.H.BS |
| Mounting | Head-mount temperature transmitter family |
| Sensor input | Universal RTD, thermocouple, resistance or millivolt input |
| Output | 4–20 mA with selectable HART 5 / HART 7 family support |
| Measurement accuracy | 0.1% family reference; sensor and span affect total uncertainty |
| Safety capability | SIL 2 / SIL 3 according to IEC 61508 for applicable configuration |
| Variant details | Verify complete suffix, approvals, display and sensor type |
The table summarizes family or catalog values for identification and initial selection. Confirm the nameplate, environmental limits, standards, revision and options for the exact device before procurement or engineering approval.
Application and system selection
Use the transmitter to convert a sensor signal into a standardized process-control output. Select the sensor type, wiring arrangement, temperature span, thermowell and process connection together. Where sensor break detection, corrosion monitoring or safety instrumented use matters, confirm the specific configuration and proof-test requirements.
Configuration and compatibility
Compare the exact model suffix with the sensor head, input wiring and HART host. Check whether the order includes an LCD, hazardous-area approval and the required sensor-error behavior. A TTH200 is a single-input design; applications needing two-sensor redundancy or drift monitoring should be assessed against the TTH300 instead of assuming equivalent behavior.
Related models and order-code references
The following designations are related catalog references, not automatic substitutes. Check each complete code, rating, connection, revision and application requirement before selecting a variant.
- TTH200-E1-H-BS-C6
- TTH200-E1-H-BS-CS-EM-GHE-M5
- TTH200-E1-H-BS-CS-EM-SE-M5
- TTH200-E1.H.BF
- TTH200-S1.H.BS 4-WIRE
- TTH200-Y0-H-D3
- TTH200-Y0-H.BS-Z2.C07.M5
- TTH200-Y0HBS
- TTH200-Y0HBS-EM.M5
- TTH200..E1.H.BS.C4.EM.GHA.M5
- TTH200..E1.H.BS.CS.EM.GHA.M5
- TTH200.E1.H.BF
- TTH200.E1.H.BS
- TTH200.E1.H.BS-.EM..GHE.Z2.C07.M5
- TTH200.E1.H.BS.EM.M5
- TTH200.Y0.H.BF
- TTH200.Y0.H.BF-Z2.C07
- TTH200.Y0.H.BF-.EM.GHE.D3.Z2.C07
- TTH200.Y0.H.BF.EM.GHE.Z2.C05.M5
- TTH200.Y0.H.BF.EM.M5
- TTH200.Y0.H.BS
- TTH200.YO.H.BF-EM.GHE.M5
- TTH200E1.H.BS.C4.EM.GHA.M5
- TTH200E1.H.BS.CS.EM.GHA.M5
- TTH200E1HBSEMM5
- TTH200E1HBSZ2C07M5
- TTH200Y0HBFC4EMGHEM5
- TTH200Y0HBFEMGHEM5
- TTH200Y0HBFEMGHEZ2C07M5
- TTH200Y0HBS
- TTH200Y0HBSZ2C07M5
Installation and commissioning
Install the head transmitter with secure sensor leads and adequate separation from power conductors. Configure sensor type, wiring, damping, range and failure current using a supported HART tool. Simulate at least two known temperatures or equivalent input signals, check loop scaling and document the final range and device tag.
Replacement and procurement information
For a quotation or replacement review, provide the complete designation TTH200-E1.H.BS, the order code where applicable, serial or hardware revision, quantity, operating environment, connected equipment and required delivery date. Include a legible nameplate image and relevant wiring, loop or switchgear drawing so the exact interface and configuration can be checked.
Ask the supplier to confirm accessories, revision compatibility and any approved successor in writing. Do not select solely from a family name or product photograph. Follow the current ABB installation and safety instructions for the exact unit.