ABB 1SVR730885R3300, CM-MPS.21S | 180–280 V AC and Neutral Monitoring

description:Technical identification and selection guidance for ABB 1SVR730885R3300, CM-MPS.21S, including verified family data, system compatibility and configuration checks....
BASIC INFO

1SVR730885R3300, CM-MPS.21S: CM-MPS.21S relay: phase, voltage and neutral supervision

The ABB CM-MPS.21S is a multifunction three-phase monitoring relay for systems with neutral. ABB lists an 180–280 V AC line-to-neutral measuring range, two changeover outputs and monitoring for phase failure, phase sequence, over/undervoltage, phase unbalance and interrupted neutral. The trip delay can be selected from instantaneous to 30 seconds.

Key technical data

Technical itemVerified value / selection note
TypeCM-MPS.21S
Order code1SVR730885R3300
Supply / measuring voltage180–280 V AC line-to-neutral
FunctionsPhase failure/sequence, over/undervoltage, unbalance and interrupted neutral
Output2 c/o (SPDT) contacts
Trip delayInstantaneous or adjustable 0.1–30 s
TerminalsScrew terminals

The table summarizes family or catalog values for identification and initial selection. Confirm the nameplate, environmental limits, standards, revision and options for the exact device before procurement or engineering approval.

Application and system selection

Use the relay when the application needs more than phase sequence alone, such as voltage-window supervision or neutral monitoring. Set thresholds and delay to match the load and control response; nuisance-trip immunity and equipment ride-through should be considered. Determine whether the output should alarm, inhibit starting or trip a contactor.

Configuration and compatibility

Check that the neutral-referenced voltage and line configuration match the relay. Compare screw terminals, output contact ratings, selectable delay and front-panel settings with the control design. Its functions differ from the simpler CM-PFS.S, so choose the exact model by the required measurements rather than the shared CM family name.

Related models and order-code references

The following designations are related catalog references, not automatic substitutes. Check each complete code, rating, connection, revision and application requirement before selecting a variant.

  • 1SVR730884R3300 CM-MPS.41S
  • CM-MPS.21P, 1SVR740885R3300
  • CM-MPS.21S
  • CM-MPS.41S
  • CM-MPS.41S 1SVR730884R3300
  • CM-MPS.43S, 1SVR730884R4300

Installation and commissioning

Install in the specified orientation and wire all monitored conductors according to the diagram. Confirm neutral integrity, phase order and the voltage threshold settings before putting the output into the protection chain. Test each configured fault condition, verify delay timing and record the final relay settings and contact logic.

Replacement and procurement information

For a quotation or replacement review, provide the complete designation 1SVR730885R3300, CM-MPS.21S, the order code where applicable, serial or hardware revision, quantity, operating environment, connected equipment and required delivery date. Include a legible nameplate image and relevant wiring, loop or switchgear drawing so the exact interface and configuration can be checked.