low voltage

Hotline

Moxa EDS-2005-EL Compact Five-Port Unmanaged Industrial Ethernet Switch

description:Moxa EDS-2005-EL compact five-port unmanaged industrial Ethernet switch for edge connections, power planning and suffix verification....
BASIC INFO

Adding a compact copper edge switch with the Moxa EDS-2005-EL

Copper ports5 × 10/100BaseT(X) RJ45
Product modelEDS-2005-EL
Switch classUnmanaged Fast Ethernet
Power12/24/48 VDC input options
HousingMetal, IP40-rated
MountingDIN-rail; optional wall-mounting kit
Temperature-10 to 60°C standard; verify the T variant

 

Is an unmanaged switch the right fit?

Moxa EDS-2005-EL is a compact unmanaged industrial Ethernet switch for simple copper edge connections. It provides five 10/100BaseT(X) ports in a metal housing and supports 12/24/48 VDC input. It may suit a small local network segment where managed features are not required, but selection should start with the number of endpoints, uplink arrangement, panel space and power supply available at the installation point.

 

Count the final devices and the upstream connection before specifying the EDS-2005-EL. The uplink normally consumes one of the five interfaces, so a five-port label does not necessarily mean five field devices plus an uplink. If the network requires fiber, VLAN configuration, remote diagnostics, ring redundancy or managed security controls, compare another switch class rather than extending the EDS-2005-EL beyond its unmanaged role.

 

Panel installation and power

The EDS-2005-EL uses a metal IP40-rated housing and supports DIN-rail mounting; a wall-mounting kit is optional. Reserve space for the removable power terminal block, RJ45 plugs and cable bend radius. Confirm the supply voltage and polarity before energizing. Its standard operating range is -10 to 60°C, while the EDS-2005-EL-T is the wide-temperature variant; match the suffix to the cabinet conditions.

 

On first power-up, verify link indicators at both ends and test the path from an endpoint through the EDS-2005-EL to the upstream network. Label ports with the connected device and uplink route. Record the power source, temperature range, mounting method and network topology so a future replacement uses the same operating assumptions.

 

Traffic behavior and variant control

The EDS-2005-EL series includes QoS and broadcast storm protection settings through DIP switches. Check the current Moxa documentation and the network design before changing those settings; a traffic-control option can affect multicast or discovery behavior. If PROFINET is used, verify the applicable hardware revision and project requirements instead of assuming that every production revision has identical conformance.

 

For a purchase request, provide the EDS-2005-EL code, required port count, input voltage, ambient temperature, mounting preference and whether managed functions are required. The related EDS-2005-ELP uses a different housing variant, and the T suffix changes the temperature rating. Confirm the full label rather than treating close model names as automatic substitutes.

 

Related model references

  • EDS-2005-ELP
  • EDS-2005-EL-T

 

 

Pre:Moxa AWK-1131A-EU Industrial WLAN AP/Bridge/Client for European-Band Deployments Next:Moxa 5105-MB-EIP Modbus RTU/ASCII/TCP to EtherNet/IP Gateway for Industrial Data Integration