low voltage

Hotline

Endress+Hauser TM131-LPDD0/101 iTHERM ModuLine thermometer for Industrial Temperature Points

description:Endress+Hauser TM131-LPDD0/101 iTHERM ModuLine thermometer for industrial RTD or thermocouple temperature measurement and exact-code sourcing....
BASIC INFO

Configuration Checks for Endress+Hauser TM131-LPDD0/101 iTHERM ModuLine thermometer

Endress+Hauser TM131-LPDD0/101 iTHERM ModuLine thermometer is a configured industrial temperature assembly from the modular TM131 family. It can be specified with RTD or thermocouple sensing, a protection tube or an existing onsite thermowell, and different head, transmitter, approval and process-connection options.

Code and family identification

Short referenceTM131-LPDD0/101
Extended order codeTM131-AABBCCB2BA8AGAB2HH3AA1
FamilyiTHERM ModuLine TM131
Instrument typeModular industrial RTD/TC thermometer
Typical purchase caseConfigured replacement or new temperature point

Sensor selection is configuration-dependent

The TM131 family supports multiple Pt100 and thermocouple classes. Endress+Hauser publishes family temperature ranges from -200 °C for selected Pt100 constructions up to 1,100 °C for selected Type K or Type N thermocouples. Pressure can be up to 100 bar and immersion lengths up to 4,500 mm, but only when the chosen construction permits it.

Engineering questions before ordering

  • Is the sensor RTD or thermocouple, and what accuracy class is required?
  • What insertion length, stem diameter and response time are needed?
  • Will the assembly use its own protection tube or an existing thermowell?
  • Which process connection, head material and cable entry are required?
  • Is a head transmitter, display or hazardous-area approval included?

For Endress+Hauser TM131-LPDD0/101 iTHERM ModuLine thermometer replacement, photograph the complete nameplate and verify the insertion length and mechanical connection. A TM131 with a different suffix may fit the same family description while being mechanically or electrically unsuitable.

Quotation package

Send both TM131-LPDD0/101 and TM131-AABBCCB2BA8AGAB2HH3AA1, plus quantity, operating temperature, connection details, destination and delivery requirement. Site drawings or thermowell data are useful when available.

Official Endress+Hauser iTHERM ModuLine TM131 information.

Pre:Tank Inventory Review for Endress+Hauser NMT81-154U90 Prothermo average temperature probe Next:Replacement Planning for Endress+Hauser TM131-LPDD0/115 iTHERM ModuLine thermometer