Danfoss 132F0002 FC 51 micro drive: supply, motor current and installation checks
Danfoss 132F0002 is an ordering number in the VLT Micro Drive FC 51 range. Danfoss lists 132F0002 as a 0.37 kW unit for a single-phase 200–240 V supply, with a 2.2 A nominal output-current entry. This shared main picture illustrates the Danfoss drive category; it is not a photograph of the exact 132F0002 unit.
Key technical data
| Technical item | Verified value / selection note |
|---|---|
| Complete order number | 132F0002 |
| Manufacturer family | Danfoss VLT Micro Drive FC 51 |
| Published motor power | 0.37 kW in the FC 51 ordering table |
| Input supply | Single-phase 200–240 V AC for 132F0002 |
| Nominal output current | 2.2 A in the manufacturer ordering table |
| Product function | Variable-frequency speed control for a suitable AC motor |
| Exact configuration | Confirm type-code suffix, EMC/filter and enclosure from the installed label |
| Selection rule | Check motor data, site supply and wiring before replacement |
The Danfoss 132F0002 details above describe the exact reference; final selection must also match the printed label and the installed equipment. The shared product image is only a category reference.
Why the full order number matters
The number 132F0002 identifies a specific entry in the FC 51 ordering range. Other 132F numbers can have different motor ratings, supply phases, nominal currents or enclosure conditions. Keep the printed type code and the sales number together when requesting a quotation for Danfoss 132F0002.
Electrical fit before replacement
Before fitting Danfoss 132F0002, compare the actual mains voltage and phase with the existing installation. Record the motor nameplate voltage, current and power, and compare the application load with the published drive rating. A visually similar small drive is not enough evidence for electrical substitution.
Panel, wiring and setup
Check cable entry, ventilation clearance, protective earth, motor wiring and any external controls for 132F0002. Save or document the parameter set from an existing unit before removal. After installation, commission the drive using the motor data and the site's approved procedure rather than copying settings blindly.
Commissioning and acceptance
For Danfoss 132F0002, verify start/stop command, speed reference, rotation direction and fault response with the connected equipment. Confirm that the motor current remains within the approved limit under the real load. Record the final type code, settings and test result for later service.
Similar-looking Danfoss order references
These 132F-looking order strings are grouped for search and enquiry. They may represent different FC 51 ratings or configurations and are not default substitutes for 132F0002.
Final order and receiving review
For Danfoss 132F0002, provide the full printed model, application duty, electrical or process interface, and current site documentation when requesting a quote. Do not approve a similar-looking number as a drop-in replacement without checking its own manufacturer data.
On receipt, inspect the Danfoss 132F0002 label and physical interfaces against the agreed order. Record condition, supplied accessories and the commissioning result so later maintenance enquiries can use the complete identity.