Danfoss 060-110191 KP1 low-pressure switch: settings and connection checks

Danfoss 060-110191 identifies a KP1 refrigeration low-pressure switch. The verified manufacturer details below apply to this order number; other codes that look similar may be different parts. The common category image is a reference collage, not a photograph of the exact Danfoss 060-110191 item.

Key technical data

Technical itemVerified value / selection note
Complete order number060-110191
Manufacturer / item classDanfoss KP1 refrigeration low-pressure switch
Regulation range-0.2 to 7.5 bar Pe
Differential range0.7 to 4 bar
Contact / resetSPDT / automatic reset
Pressure port1/4 in male flare; IP44 enclosure
Image scopeShared Danfoss category collage, not an exact-model photograph
Final selection ruleMatch complete installed label and manufacturer record before substitution

Setpoint review

For Danfoss 060-110191, record the existing cut-in, cut-out and differential before disturbing the old switch. Confirm that the target operating points lie within the published KP1 adjustment range.

Circuit and port

For Danfoss 060-110191, verify the controller's SPDT wiring, pressure port, flare connection and cable entry. Similar order numbers may differ in reset action, enclosure or connection design.

Commissioning

For Danfoss 060-110191, use a calibrated pressure reference to observe switching at the required settings. Verify alarm and restart behavior in the actual refrigeration circuit before handover.

Similar-looking Danfoss order references

The following codes resemble Danfoss 060-110191 in the supplied order-number set. They are search and enquiry references only, not interchangeability approvals. Verify every code's own function, ratings, interfaces and availability before ordering.

060-110366
060-110866
060-113366
060-117166
060-117366
060-121766
060-124391
060-124566
060-206466
060-310366
060-312166
060-316966
060-319266
060-526966

Quotation and receiving checklist

When requesting Danfoss 060-110191, provide the full printed order number, the installed equipment identity and the operating duty. Compare the supplier's quotation to the exact Danfoss 060-110191 record, including package quantity and any accessory boundary. A visually matching item with another suffix needs a separate engineering decision.

On receipt of Danfoss 060-110191, check the label, connector or mechanical interfaces, packaging and condition. Document the approved settings or test result after installation so the maintenance record continues to identify Danfoss 060-110191 unambiguously.

 

 

Pre:Danfoss 052F4032 EBI4 HPM Ignition Unit | 230 V Burner Service, Output and Housing Checks Next:Danfoss 061B000066 MBC 5100 Pressure Switch | Range, IP65 Enclosure and Control Contact Review