ABB XT1H 160TMD 160-1600 3P FF technical application brief
Use ABB XT1H 160TMD 160-1600 3P FF as the complete reference for this equipment position. Matching a family name alone does not establish module fit, electrical ratings or permitted service configuration.
Technical parameters and limits
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | XT1H 160TMD 160-1600 3P FF |
| Product family | XT1H |
| Component role | Tmax XT1H three-pole molded-case breaker |
| Frame | XT1H 160 |
| Poles | 3 |
| Trip | TMD thermal-magnetic |
| Mounting | Fixed front-terminal |
| ABB code | 1SDA067454R1 |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The XT1H 160TMD 160-1600 3P FF values above are selection checkpoints. Check the fitted nameplate and current ABB installation documents before releasing a replacement or changing field wiring.
Before energizing
Isolate the affected circuit before working on XT1H 160TMD 160-1600 3P FF, following the plant procedure. Preserve wiring photos, parameters and a known-good diagnostic snapshot.
Seat and terminate XT1H 160TMD 160-1600 3P FF with the specified accessories. Check grounding, segregation and installation environment before power is restored.
Asset purpose
ABB XT1H 160TMD 160-1600 3P FF is intended to protect the specified 160 A feeder. Record the cabinet, circuit or loop tag and the controlled process so the purchase is linked to a defined duty.
A XT1H 160TMD 160-1600 3P FF replacement request should identify the installed hardware revision and the reason for change, including any active alarm or failed test.
Connection evidence
For XT1H 160TMD 160-1600 3P FF, inspect fault capacity, conductor, TMD setting, trip coordination and mounting. Verify the exact terminals, power path, mechanical keying and software interface against the site drawing.
If a proposed XT1H 160TMD 160-1600 3P FF has different connectors or ratings, stop the swap and document the engineering decision rather than assuming series compatibility.
Diagnostic baseline
For later troubleshooting of XT1H 160TMD 160-1600 3P FF, capture supply status, module diagnostics, output state and the relevant process reading. This makes it possible to distinguish a device fault from a field issue.
Compare XT1H 160TMD 160-1600 3P FF with the pre-change baseline after installation. Investigate unexpected alarms, temperature, noise or switching before returning the asset to normal duty.
Acceptance test
For XT1H 160TMD 160-1600 3P FF, record mechanical and approved trip-unit tests. Record the result, witness and acceptance date, including any temporary bypass or inhibited alarm that must be removed.
Close the XT1H 160TMD 160-1600 3P FF work order only when as-left settings and drawings reflect the actual installation.
Other configuration references
These XT1H references are indexed alongside ABB XT1H 160TMD 160-1600 3P FF for enquiry. Different options, ratings or approvals may apply, so the codes are not automatic substitutes.
No additional unassigned XT1H designation is grouped under XT1H 160TMD 160-1600 3P FF.
Procurement handoff
Quote ABB XT1H 160TMD 160-1600 3P FF exactly, including the application tag, required accessories, installation conditions and documentation revision.
At receipt, compare the supplied XT1H 160TMD 160-1600 3P FF against the approved code before fitting. Retain the acceptance evidence with the asset record.