low voltage

Hotline

ABB TF65-47 Thermal Motor Overload Relay — Selection Evidence and Site Acceptance

description:Technical identification and selection guidance for ABB TF65-47, including verified family data, system compatibility and configuration checks....
BASIC INFO

Field selection notes for TF65-47

TF65-47 is a thermal motor overload relay for a defined industrial installation. When requesting TF65-47, keep its complete printed designation, hardware revision and project context together so that purchasing and engineering review the same component.

Technical identification and selection data

Technical itemVerified value / selection note
Complete designationTF65-47
Product familyTF65
Component rolethermal motor overload relay
Setting range36 to 47 A
Trip class10
Order code1SAZ811201R1004
ContactsNC trip and NO signal
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

The TF65-47 data above identifies the published function and key selection checks. A rating or connection shared with another device does not establish an approved replacement for TF65-47.

Match the interface before ordering

The critical cross-check for TF65-47 is: Set the dial from the motor nameplate and check contactor mounting, ambient conditions and reset mode. A similar product outline, series name or current class alone is not enough.

Ask the supplier to identify any deviations from TF65-47 in connection hardware, function, approvals and accessories. Resolve them against the engineering drawing before accepting a substitute.

Where this item works

For TF65-47, the intended duty is: Protect a compatible contactor starter from sustained overload and phase failure. Capture the actual connected load or signal, site environment and operating sequence before purchase.

The installation record for TF65-47 should include a nameplate photograph, panel drawing and the failed unit's setting or software version when applicable.

Installation and return-to-service proof

For TF65-47, the controlled acceptance method is: Test trip indication, STOP function, auxiliary contacts and motor shutdown with the approved procedure. Record the actual results, not merely a pass/fail impression.

Before returning the equipment containing TF65-47 to production, verify isolation, protective coordination, terminal identification and any interlock or safety-related response.

Same-series ordering references

These codes share the TF65 grouping with TF65-47, but option strings can alter ratings, wiring, firmware or certifications. They are not automatically interchangeable with TF65-47.

  • 1SAZ811201R1002 TF65-33
  • 1SAZ811201R1003 TF65-40
  • 1SAZ811201R1006 TF65-60
  • TF65-53
  • TF65-60
  • TF65-60,36-47A

Buyer handover record

Quote TF65-47 in full, state quantity and destination, and attach the relevant panel photograph and drawing. Confirm whether accessories are included in the offered supply.

At receipt, compare the supplied label with TF65-47 and document any difference before installation. Retain the final part identity and the TF65-47 acceptance test with the asset history.

 

 

Pre:Procurement Dossier: ABB MO132-1.6 1SAM360000R1006 Magnetic-Only Manual Motor Starter and Compatibility Points Next:ABB X20BC0043 Legacy Canopen X20 Bus Controller | Integration Map and Technical Selection