ABB S804N-B80 Four-Pole S800N High-Performance Breaker | Interface, Ratings and Test Record

description:Technical identification and selection guidance for ABB S804N-B80, including verified family data, system compatibility and configuration checks....
BASIC INFO

Service and interface record: ABB S804N-B80

Use ABB S804N-B80 as the complete reference for this equipment position. Matching a family name alone does not establish module fit, electrical ratings or permitted service configuration.

Technical parameters and limits

Technical itemVerified value / selection note
Complete designationS804N-B80
Product familyS804N
Component rolefour-pole S800N high-performance breaker
Poles4
Rated current80 A
Trip curveB
Icu36 kA family reference
Order code2CCS894001R0805
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

The S804N-B80 values above are selection checkpoints. Check the fitted nameplate and current ABB installation documents before releasing a replacement or changing field wiring.

Asset purpose

ABB S804N-B80 is intended to protect a four-pole high-current distribution circuit. Record the cabinet, circuit or loop tag and the controlled process so the purchase is linked to a defined duty.

A S804N-B80 replacement request should identify the installed hardware revision and the reason for change, including any active alarm or failed test.

Connection evidence

For S804N-B80, inspect fault level, neutral switching, cable rating and busbar fit. Verify the exact terminals, power path, mechanical keying and software interface against the site drawing.

If a proposed S804N-B80 has different connectors or ratings, stop the swap and document the engineering decision rather than assuming series compatibility.

Before energizing

Isolate the affected circuit before working on S804N-B80, following the plant procedure. Preserve wiring photos, parameters and a known-good diagnostic snapshot.

Seat and terminate S804N-B80 with the specified accessories. Check grounding, segregation and installation environment before power is restored.

Diagnostic baseline

For later troubleshooting of S804N-B80, capture supply status, module diagnostics, output state and the relevant process reading. This makes it possible to distinguish a device fault from a field issue.

Compare S804N-B80 with the pre-change baseline after installation. Investigate unexpected alarms, temperature, noise or switching before returning the asset to normal duty.

Acceptance test

For S804N-B80, check all poles and record downstream circuit test. Record the result, witness and acceptance date, including any temporary bypass or inhibited alarm that must be removed.

Close the S804N-B80 work order only when as-left settings and drawings reflect the actual installation.

Other configuration references

These S804N references are indexed alongside ABB S804N-B80 for enquiry. Different options, ratings or approvals may apply, so the codes are not automatic substitutes.

No additional unassigned S804N designation is grouped under S804N-B80.

Procurement handoff

Quote ABB S804N-B80 exactly, including the application tag, required accessories, installation conditions and documentation revision.

At receipt, compare the supplied S804N-B80 against the approved code before fitting. Retain the acceptance evidence with the asset record.

 

 