Where S202M-K10UC fits in the installed system
Use the complete S202M-K10UC designation when tracing a fault or buying a replacement. S202M-K10UC is a two-pole K-curve AC/DC miniature breaker and its installed duty matters more than a visually similar housing.
Technical data to check first
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | S202M-K10UC |
| Product family | S202M K UC |
| Component role | two-pole K-curve AC/DC miniature breaker |
| Poles | 2 |
| Rated current | 10 A |
| Trip characteristic | K |
| Application | AC/DC, confirm voltage and polarity limits |
| Order code | 2CDS272061R0427 |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The S202M-K10UC values above identify this selection. Verify the actual nameplate, hardware revision and option set before declaring another code equivalent.
Installation handover
Isolate the circuit or process before touching S202M-K10UC; follow the site's approved safety procedure. Record cable labels, settings, accessory positions and original markings.
When S202M-K10UC is fitted, restore the approved configuration and make sure installation details match the drawings. Keep removed parts until the acceptance result is signed off.
Replacement compatibility review
For S202M-K10UC, compare circuit voltage, DC polarity, fault level, load inrush and coordination. Check the complete order code, not only the family prefix.
A proposed substitute for S202M-K10UC requires a documented comparison of electrical or process rating, terminals, communications, mechanical fit and any required settings.
Observed fault and process consequence
In this installation, S202M-K10UC is intended to protect the matching AC or DC branch circuit with its K-curve duty. Write down the fault indication, operating state and last known good reading before removal.
If S202M-K10UC trips or loses communication intermittently, separate wiring and supply faults from device faults. Capture the relevant alarm history and field measurements.
Acceptance evidence
The practical test for S202M-K10UC is to check the marked poles, wiring and approved circuit-protection test. Log the expected result, actual result, date and responsible technician.
Do not close a S202M-K10UC replacement ticket on visual inspection alone. Confirm the normal function and the planned failure or alarm response where safely testable.
Other codes in this series
The following S202M K UC designations are placed under S202M-K10UC for enquiries. Ratings, hardware versions and options may differ; these codes are not declared interchangeable.
- S202M-K16UC
- S202M-K20UC
- S202M-K25UC
- S202M-K2UC
- S202M-K6UC
Records to keep
File the S202M-K10UC order identification, inspection result, settings backup and commissioning evidence with the equipment record.
If S202M-K10UC is later reordered, compare the current installation record with the supplier's complete designation before the purchase is released.