ABB PM862K01 selection decision record
Start the ABB PM862K01 enquiry with a precise equipment identity and a defined plant function. The verified values below establish a technical baseline; they do not replace checking the delivered unit.
Verified parameters and fit limits
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | PM862K01 |
| Product family | PM862 |
| Component role | AC 800M controller kit |
| Kit | PM862K01 |
| ABB article | 3BSE076940R1 |
| System | AC 800M |
| Controller | PM862 CPU with matching base and system accessories |
| Interfaces | Control-network and serial ports; verify selected kit |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
Before signing off PM862K01, check the current ABB documentation and the actual nameplate. Family-level information must not be used as a guaranteed option for every configuration.
Which interfaces must match?
For PM862K01, confirm CPU pairing, firmware, baseplate, network and project backup. Compare the original label, mounting, field terminals and power/control supplies with the ABB product reference.
Keep the PM862K01 electrical or network interface unchanged unless engineering has approved the revised drawing, settings and test scope.
What problem does it solve?
ABB PM862K01 is selected to run the approved AC 800M application. State the actual circuit, loop or motor tag and the operating problem before deciding on a replacement.
A request for PM862K01 without site duty, installed revision or failure evidence can lead to a technically different part being offered.
What can cause a poor match?
A PM862K01 suffix or order-code difference may identify another coil, contact set, protocol, release, shaft or voltage. A matching appearance is not interchangeability evidence.
If the supplied PM862K01 differs from the approved item, quarantine it for review rather than changing field wiring to make it fit.
What changes at installation?
Installing PM862K01 may affect adjacent wiring, panel access and auxiliary accessories. Check clearance and isolate the correct energy sources under the site's permit system.
Before disturbing PM862K01, save photos, configuration, parameter values and an alarm baseline. Keep removed parts identifiable until acceptance is signed.
What should purchasing retain?
The ABB PM862K01 record should include the complete designation, required accessories, label evidence and the current installation manual revision.
For any proposed substitute to PM862K01, obtain written confirmation of every changed technical characteristic and the site's acceptance.
How is performance proved?
After approved installation of PM862K01, load the validated project and test I/O. Use only documented safe test methods and include connected equipment behavior.
Record the PM862K01 as-left results, asset tag, revision, date and witness. Restore alarms, interlocks and normal control before service handover.
Other codes in this same series
The following PM862 references can accompany an ABB PM862K01 enquiry. Suffix changes can affect ratings, fit or approvals, so none is an automatic replacement.
- PM862K02
Enquiry and acceptance handoff
Quote ABB PM862K01 exactly, include the asset tag and duty, and request confirmation of any missing accessories or alternative build.
Keep the approved PM862K01 comparison, installation checks and test results in the maintenance record.