FEP632.Y0.A2.0100.D2.T1.C.1.G.2.A.70.Y.0.Y0.A.DR0.DS0.C0.CMA: sensor and transmitter matching
ABB identifies FEP632 as the remote-mount ProcessMaster FEP630 sensor arrangement. Published family accuracy for liquids starts at 0.4% of the measured value, with options; the long ordering suffix requires independent confirmation for the supplied pipe size and materials.
Verified identification and technical data
| Technical item | Verified value / selection note |
|---|---|
| Full designation | FEP632.Y0.A2.0100.D2.T1.C.1.G.2.A.70.Y.0.Y0.A.DR0.DS0.C0.CMA |
| Measurement | Electromagnetic volume flow |
| Mounting family | Remote-mount ProcessMaster FEP632 |
| Liquid accuracy | 0.4% of measured value family standard; 0.3%/0.2% options |
| Conductivity | >5 µS/cm family requirement; higher for demineralized water |
| Sensor size range | DN3–DN2000 family; decode exact ordered size |
For FEP632.Y0.A2.0100.D2.T1.C.1.G.2.A.70.Y.0.Y0.A.DR0.DS0.C0.CMA, the table is an identification and selection aid. A nameplate, ABB order record and the actual installation still govern the final configuration.
Confirm the full type, revision and installation limits before treating any related code as a replacement.
Application decision
Review the duty before choosing FEP632.Y0.A2.0100.D2.T1.C.1.G.2.A.70.Y.0.Y0.A.DR0.DS0.C0.CMA. Evaluate conductive-liquid properties, minimum flow, full-scale velocity, empty-pipe conditions and available straight pipe. Remote transmitter cable routing is part of the measurement design.
The decision for FEP632.Y0.A2.0100.D2.T1.C.1.G.2.A.70.Y.0.Y0.A.DR0.DS0.C0.CMA should record actual load or process limits, operating environment, normal behavior and the response to a fault. This avoids a selection based only on a familiar series name.
Order and compatibility gate
When specifying FEP632.Y0.A2.0100.D2.T1.C.1.G.2.A.70.Y.0.Y0.A.DR0.DS0.C0.CMA, Decode the complete sensor and transmitter options against ABB's order record, including lining, electrode, flanges, pressure, approvals and communications. A FEP631 integral unit is related but not an automatic substitute.
Send the full designation FEP632.Y0.A2.0100.D2.T1.C.1.G.2.A.70.Y.0.Y0.A.DR0.DS0.C0.CMA, hardware or serial revision, quantity, delivery need and nameplate photograph with the RFQ. Require written confirmation of any proposed successor or option-code change.
Installation and proving
For FEP632.Y0.A2.0100.D2.T1.C.1.G.2.A.70.Y.0.Y0.A.DR0.DS0.C0.CMA, Drain and isolate the line before removal. Check full-bore installation, grounding, remote cable integrity, zero and output scaling with the process safely returned to flow.
Record the as-left settings, test results and installed interfaces of FEP632.Y0.A2.0100.D2.T1.C.1.G.2.A.70.Y.0.Y0.A.DR0.DS0.C0.CMA. Make the asset record searchable by the complete designation, not only by a short family label.
Same-series designation index
The codes below share a product family or an identified order-code relationship with FEP632.Y0.A2.0100.D2.T1.C.1.G.2.A.70.Y.0.Y0.A.DR0.DS0.C0.CMA. They may differ in rating, software, connections, options or approvals; none is automatically interchangeable.
- FEP632.Y0.A2.0100.D2.T1.C.1.G.2.A.70.Y.0.Y0.A.DR0.DS0.C0.CMA.CRP.F5.J6.K0
Handover record
The buyer and site engineer should agree on a single verified configuration for FEP632.Y0.A2.0100.D2.T1.C.1.G.2.A.70.Y.0.Y0.A.DR0.DS0.C0.CMA, including accessories, documentation and the accepted test procedure. Keep deviations visible to both procurement and maintenance.
Retain FEP632.Y0.A2.0100.D2.T1.C.1.G.2.A.70.Y.0.Y0.A.DR0.DS0.C0.CMA in the purchase order, asset register and commissioning record. ABB family specifications help identify the device, but the approved project documents determine whether it is suitable for this installation.