ACS880-104-0011A-3+N8010+P904: engineering checks for this ACS880-104 multidrive inverter module
ACS880-104-0011A-3+N8010+P904 is an ABB ACS880-104 multidrive inverter module. The full ACS880-104-0011A-3+N8010+P904 designation, not a family photograph, is the starting point for a technically valid purchase or replacement.
Technical selection record
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | ACS880-104-0011A-3+N8010+P904 |
| Complete designation | ACS880-104-0011A-3+N8010+P904 |
| Series | ACS880-104 |
| Architecture | DC-fed inverter module for a multidrive lineup |
| Selection focus | Size the inverter against the motor and shared DC-bus architecture, not as a complete standalone AC-input drive. |
| Electrical rating | Confirm exact unit nameplate and ABB rating table |
| Option string | Decode each suffix against the order record |
The architecture above is a verified series characteristic. ABB ratings and options for ACS880-104-0011A-3+N8010+P904 must still be checked against the exact nameplate, the current hardware manual and the original order record.
Integration boundary
For the complete ACS880-104-0011A-3+N8010+P904 code, Confirm supply unit, DC link, control unit, cooling, cabinet integration and all N/P options in the order code.
Review the electrical drawing, cooling path, cabinet or wall mounting, cable terminations and protection coordination. A different ACS880-104 option set can change the delivered interfaces and approvals.
Site acceptance test
When recommissioning ACS880-104-0011A-3+N8010+P904, Test DC-link readiness, inverter enable, motor identification and protective trips under the approved startup plan.
Log the observed input and motor-side values, alarms, parameter backup and as-left control source. Clear temporary forces and obtain the plant's electrical sign-off before normal service.
Duty and load question
For ACS880-104-0011A-3+N8010+P904, Size the inverter against the motor and shared DC-bus architecture, not as a complete standalone AC-input drive.
Record continuous current, overload demand, acceleration or braking duty, motor nameplate values and the available supply. Those site inputs determine whether ACS880-104-0011A-3+N8010+P904 fits the installed machine.
Same-series ordering references
The following ACS880-104 designations are related order-code references only. Different current sizes, voltages and suffixes are not interchangeable without an engineering check. The list is not a universal replacement table.
- ACS880-104-0014A-5+K454+L502+N5050+J425
- ACS880-104-0018A-3+N8010+P904
- ACS880-104-0018A-3+OJ414
- ACS880-104-0025A-3+N8010+P904
- ACS880-104-0035A-3+N8010+P904
- ACS880-104-0035A-5 + P922
- ACS880-104-0035A-5+P922
- ACS880-104-0035A-7
- ACS880-104-0035A-7+Q950+N671
- ACS880-104-0050A-3+N8010+P904
- ACS880-104-0050A-3+P904
- ACS880-104-0061A-3+N8010+P904
- ACS880-104-006A0-3+N8010+P904
- ACS880-104-0078A-3+N8010+P904
- ACS880-104-0082A-7+F272
- ACS880-104-0094A-5+K454+N5050+J425
- ACS880-104-0100A-3+OJ414
- ACS880-104-0130A-7
- ACS880-104-0140A-3 +N8010+P904
- ACS880-104-0140A-3+P904+F272
- ACS880-104-0140A-7+N5050+N8015
- ACS880-104-0170A-3+N8010+P904
- ACS880-104-0210A-3+F272+P904
- ACS880-104-0210A-3+N8010+P904
- ACS880-104-0220A-7+P904 R7I
- ACS880-104-0250A-3+N8010+P904
- ACS880-104-0300A-5+F272+K454+L502+N5050+J425
- ACS880-104-0340A-7+E205
- ACS880-104-0340A-7+E205+P904
- ACS880-104-0340A-7+E205+P922
- ACS880-104-0410A-7+C183+E205+G304+P922
- ACS880-104-0410A-7+E205
- ACS880-104-0410A-7+E205+N8207+P904
- ACS880-104-0410A-7+E205+P904
- ACS880-104-0530A+C183+E205
- ACS880-104-0530A-7+C183+E205+V112
- ACS880-104-0530A-7+E205
- ACS880-104-0530A-7+E205+P904
- ACS880-104-0590A-5+C172+C183+E205+G304
- ACS880-104-0590A-5+E205+P922
- ACS880-104-0600-7
- ACS880-104-0600A+C183+E205
- ACS880-104-0600A-7
- ACS880-104-0600A-7+C183+E205
- ACS880-104-0600A-7+C183+E205+N8201
- ACS880-104-0600A-7+C183+E205+P992+V112
- ACS880-104-0600A-7+C183, 3AUA0000103636
- ACS880-104-0600A-7+E205
- ACS880-104-0600A-7+E205+N8201
- ACS880-104-0600A-7+E205+P904
- ACS880-104-0600A-7+E205+P922+V112
- ACS880-104-0600A-7E205N8207P904
- ACS880-104-0640A-3
- ACS880-104-0640A-3+E205
- ACS880-104-0640A-3+E205+P904
- ACS880-104-0640A-3+E205+V112
- ACS880-104-0810A-5+C172+C183+E205+G304
- ACS880-104-0900A-3
- ACS880-104-0900A-3+E205+P904
- ACS880-104-0900A-3E205N8207P904
RFQ and handover details
Quote ACS880-104-0011A-3+N8010+P904 exactly and include the motor data, site voltage, environmental conditions, original parameters, fitted options and delivery requirement. Ask the supplier to identify an approved successor in writing if the exact item is unavailable.
Keep ACS880-104-0011A-3+N8010+P904 in the purchase order and asset register. Before energizing a replacement, the maintenance team should confirm mechanical fit, terminals, safety functions and the agreed startup test.