low voltage

Hotline

ABB 2CSR256040R1104 Replacement Record for 3P+N residual-current breaker with overcurrent protection and Circuit Checks

description:Technical identification and selection guidance for ABB 2CSR256040R1104, including verified family data, system compatibility and configuration checks....
BASIC INFO

ABB 2CSR256040R1104 installation dossier

ABB 2CSR256040R1104 is a 3P+N residual-current breaker with overcurrent protection in the DS203NC three-phase RCBOs group. The shared category image is a reference, not proof of the exact supplied unit.

For ABB 2CSR256040R1104, the order code and verified manufacturer description establish the article. Circuit ratings and compatibility must also match the installed equipment.

Technical identification and installation limits

Technical itemVerified value / selection note
Complete designation2CSR256040R1104
Product familyDS203NC three-phase RCBOs
Component role3P+N residual-current breaker with overcurrent protection
Exact ABB order reference2CSR256040R1104
ABB product seriesDS203NC three-phase RCBOs
ABB order code2CSR256040R1104
Manufacturer designationDS203NC C10 AC30
Poles3P+N
WidthFour modules in ABB description
Related variantsC16 AC30 and C16 A30 have different codes
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

03 | Purchase with evidence

Put ABB 2CSR256040R1104 in full on the purchase line. Attach a photograph of the installed nameplate and the approved drawing revision.

Before dispatch, confirm ABB 2CSR256040R1104 packaging, revision and supplied accessories. A supplier's generic family photo cannot verify the selected variant.

01 | Identify the circuit

Locate ABB 2CSR256040R1104 on the approved single-line, control or service drawing. Record what the part is expected to protect the specified three-phase circuit.

For ABB 2CSR256040R1104, note the real host equipment and duty. A related order code can have a different current, supply, contact layout, kit count or physical fit.

02 | Resolve the interface

Compare rated current, residual type, neutral and feeder scheme for ABB 2CSR256040R1104. Include termination details, adjacent devices, protective clearances and the intended operating state.

If ABB 2CSR256040R1104 is being proposed as a replacement, obtain a written comparison of the old and new designations. Do not rely on the manufacturer prefix alone.

04 | Prepare safe access

Isolate every relevant source before handling ABB 2CSR256040R1104. Capacitors, power semiconductors, control feeds and connected loads may retain hazardous energy.

Follow ABB and site safety procedures for ABB 2CSR256040R1104; confirm the required safe state and document original wiring, polarity, settings and mechanical orientation.

05 | Install and prove

Mount ABB 2CSR256040R1104 only in its approved host and restore all covers, bonding and terminal clearances. Then prove correct trip and all-pole behavior.

Record measured results for ABB 2CSR256040R1104, including normal and fault-state behavior. A lit indicator or a cleared alarm alone is not a complete acceptance test.

06 | Close the maintenance record

Keep ABB 2CSR256040R1104 serial or revision information, delivery label and the as-left drawing with the equipment history.

If ABB 2CSR256040R1104 has any variant boundary, carry that note into the spare-parts register so later purchases do not silently substitute another code.

Variant codes covered on this representative page

The following ABB codes are associated with ABB 2CSR256040R1104 on this page, not published as separate pages. They are not automatic substitutes; check the full designation and the affected duty before ordering.

  • 2CSR256040R1164
  • 2CSR256140R1164

Order closeout

For ABB 2CSR256040R1104, retain the approved order identity, delivery check and commissioning record.

Future ABB 2CSR256040R1104 enquiries should include the original host and circuit constraints.

ABB 2CSR visually similar order-code references

These strings are collected by their similar printed ordering-code format. They may identify different device types, electrical ratings or accessories. Listing them together does not mean they share a product series, function, approval or interchangeability. Confirm the exact ABB designation and manufacturer documentation before ordering or substitution.

2CSR145 references

  • 2CSR145001R1254

2CSR245 references

  • 2CSR245072R1064
  • 2CSR245140R1164

2CSR252 references

  • 2CSR252001R1164
  • 2CSR252140R1064
  • 2CSR252140R1164

2CSR255 references

  • 2CSR255040R1164
  • 2CSR255040R1324
  • 2CSR255050R1104
  • 2CSR255050R1164
  • 2CSR255060R1204
  • 2CSR255070R1324
  • 2CSR255080R1064
  • 2CSR255080R1104
  • 2CSR255080R1164
  • 2CSR255080R1165
  • 2CSR255080R1204
  • 2CSR255080R1254
  • 2CSR255080R1404
  • 2CSR255101R1204
  • 2CSR255161R1204
  • 2CSR255163R1104
  • 2CSR255163R1164
  • 2CSR255180R0104
  • 2CSR255180R1064
  • 2CSR255180R1065
  • 2CSR255180R1104
  • 2CSR255180R1104, DS201 C10 A30
  • 2CSR255180R1164
  • 2CSR255180R1254
  • 2CSR255201R1204
  • 2CSR255251R1204

2CSR256 references

  • 2CSR256040R1104
  • 2CSR256040R1164
  • 2CSR256140R1164

2CSR272 references

  • 2CSR272001R1064 (DS202 M AC-C6/0.03)
  • 2CSR272001R1164
  • 2CSR272140R1104

2CSR275 references

  • 2CSR275040R1104
  • 2CSR275080R1064
  • 2CSR275080R3064
  • 2CSR275151R1164
  • 2CSR275180R1044
  • 2CSR275180R1064

2CSR752 references

  • 2CSR752140R1164

2CSR755 references

  • 2CSR755080R1164
  • 2CSR755080R1324

2CSR772 references

  • 2CSR772140R1164

 

 

Pre:Specifying ABB 2CSR255163R1104 for DS301C one-module RCBOs in an Existing Panel Next:ABB 2CMA142417R1000 BWS side-operated safety switches | Technical Data and Handover Criteria