ABB 2CDS200970R0032 acceptance profile
ABB 2CDS200970R0032 names the exact bottom-fitting auxiliary contact used in this service profile. Its job is to provide an approved auxiliary indication. The category image is a reference image, not proof that the delivered ABB 2CDS200970R0032 has the same physical configuration.
Technical data for the order code
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 2CDS200970R0032 |
| Product family | S2C-H10 MCB/AFDD auxiliary contacts |
| Component role | bottom-fitting auxiliary contact |
| Exact ABB order reference | 2CDS200970R0032 |
| ABB product series | S2C-H10 MCB/AFDD auxiliary contacts |
| ABB order code | 2CDS200970R0032 |
| Manufacturer designation | S2C-H10 |
| Manufacturer product text | S2C-H10 Bottom-fitting auxiliary contact 1NO with slider for MCB + AFDD S2C-H10 |
| ABB designation | S2C-H10 |
| Contact | 1 NO with slider |
| Host | MCB + AFDD in ABB description |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
Read the ABB 2CDS200970R0032 designation alongside the installed-equipment documentation. A difference in host, frame, connector, rating or kit contents can change whether ABB 2CDS200970R0032 is suitable.
Record the current assembly
Find the existing ABB 2CDS200970R0032 position on the drawing and take a legible photograph of the installed marking. Record the host model, serial or frame identifier and revision.
For ABB 2CDS200970R0032, capture the wiring, mounting orientation and any parameter image before removing the existing component.
Compare the supply item
Compare the delivered ABB 2CDS200970R0032 label and package with the approved order. Check MCB/AFDD host, bottom fit and slider arrangement before work begins.
If another ABB 2CDS200970R0032 configuration is proposed, have the design owner review its technical identity; similarity of appearance does not establish equivalence.
Plan the isolation
Before handling ABB 2CDS200970R0032, identify every relevant electrical and mechanical energy source. Apply the approved lockout and stored-energy discharge procedure.
Keep ABB 2CDS200970R0032 installation instructions available at the work point. Observe the host manufacturer's limits for connection, torque, clearance and protective covers.
Fit and inspect
Install ABB 2CDS200970R0032 in the documented location without forcing plugs, shafts or terminals. Check that labels remain readable and routing matches the original drawing.
Inspect ABB 2CDS200970R0032 fasteners, strain relief, insulation, barriers and intended movement as relevant to this specific component.
Functional evidence
With the assembly made safe for an authorized test, prove the assigned auxiliary contact. Include the relevant alternate state or alarm condition for ABB 2CDS200970R0032.
Record the ABB 2CDS200970R0032 test steps, observed results and any deviations. Do not close the maintenance record on an unverified function.
Return-to-service decision
Compare ABB 2CDS200970R0032 behavior against the approved acceptance criteria. Review protection, cooling, communication or relay response as appropriate to the role.
Only return equipment to service when ABB 2CDS200970R0032 identification, installation and functional results have been signed off.
Keep the spare record usable
Store the complete ABB 2CDS200970R0032 order code with the supported host and the tested configuration. Keep replacement and commissioning records with the asset.
When requesting ABB 2CDS200970R0032 again, include the full designation and known variant restrictions rather than a short family label.
Service handover
State the accepted ABB 2CDS200970R0032 code in the final maintenance and procurement record.
Retain the ABB 2CDS200970R0032 test evidence for the next service intervention.