Field-fit record for ABB 2CDG110110R0011
This field-fit dossier treats ABB 2CDG110110R0011 as the representative of the MT/S KNX security terminal series. The technical table below applies to the representative order reference, while later family codes require individual verification.
Representative technical data
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 2CDG110110R0011 |
| Product family | MT/S KNX security terminal |
| Component role | eight-zone KNX security input terminal |
| Exact ABB order reference | 2CDG110110R0011 |
| ABB product series | MT/S KNX security terminal |
| Type | MT/S 8.12.2M |
| Signal groups | 8 |
| Auxiliary supply | External 12 V DC SELV |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
For ABB 2CDG110110R0011, confirm installation-specific limits and fitted options against the current ABB documentation and delivered item before use.
Asset question
ABB 2CDG110110R0011 should be evaluated against the actual equipment tag and its job: monitor passive alarm detector groups through KNX. A series name alone does not confirm that a replacement will perform the same task.
Record the operating demand, connected load or signal, and reason ABB 2CDG110110R0011 is being ordered. That record separates a service replacement from a new design choice.
Nameplate and drawing
Compare ABB 2CDG110110R0011 with the nameplate, cabinet drawing and current ABB documentation. Capture electrical or software revisions that influence the fit.
A quotation for ABB 2CDG110110R0011 should preserve the complete order identity. If the supplier suggests another code, request a written difference review for the changed rating, function and approvals.
Commissioning evidence
After safe installation of ABB 2CDG110110R0011, test each monitored input and alarm state. Use the approved isolation, energization and functional-test procedure for the site's equipment.
Save the observed state, date and drawing revision for ABB 2CDG110110R0011. A passing visual inspection is not a substitute for an electrical or functional acceptance test.
Interface walkdown
Before approving ABB 2CDG110110R0011, confirm detector wiring, auxiliary supply and alarm logic. Inspect the existing terminal numbers, space, connector or host option slot rather than relying on the product photograph.
The ABB MT/S KNX security terminal family may include variants with different ratings, connection details or functions. Treat every listed reference as a separate full designation.
Future service note
Keep ABB 2CDG110110R0011 in the asset history with the exact series and order reference. This helps the next technician distinguish this device from other MT/S KNX security terminal variants.
If ABB 2CDG110110R0011 is later replaced by a different family member, repeat the full interface and protection checks; family grouping here is for browsing, not automatic interchangeability.
Receiving inspection
At receipt, check ABB 2CDG110110R0011 for correct labeling, intact housing and complete supplied accessories. Keep the packaging reference with the maintenance order.
For ABB 2CDG110110R0011, quarantine any unit whose marking, rating or connector differs from the approved purchase specification; do not silently substitute a similar code.
Decision at handover
Release ABB 2CDG110110R0011 only when order identity, interface inspection and operational test all agree with the approved design.
Document any deviation before installing ABB 2CDG110110R0011; a variant from the same MT/S KNX security terminal series still needs its own fit check.