ABB 2CCS800900R0501 installation dossier
ABB 2CCS800900R0501 is a remote switching unit in the S800-RSU remote switching units group. The shared category image is a reference, not proof of the exact supplied unit.
For ABB 2CCS800900R0501, the order code and verified manufacturer description establish the article. Circuit ratings and compatibility must also match the installed equipment.
Technical identification and installation limits
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 2CCS800900R0501 |
| Product family | S800-RSU remote switching units |
| Component role | remote switching unit |
| Exact ABB order reference | 2CCS800900R0501 |
| ABB product series | S800-RSU remote switching units |
| ABB order code | 2CCS800900R0501 |
| Manufacturer designation | S800-RSU-H |
| Host | Multipole S800 high-performance breakers in ABB description |
| Reference standard | IEC 60947-2 in ABB description |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
03 | Purchase with evidence
Put ABB 2CCS800900R0501 in full on the purchase line. Attach a photograph of the installed nameplate and the approved drawing revision.
Before dispatch, confirm ABB 2CCS800900R0501 packaging, revision and supplied accessories. A supplier's generic family photo cannot verify the selected variant.
01 | Identify the circuit
Locate ABB 2CCS800900R0501 on the approved single-line, control or service drawing. Record what the part is expected to operate the approved breaker remotely.
For ABB 2CCS800900R0501, note the real host equipment and duty. A related order code can have a different current, supply, contact layout, kit count or physical fit.
02 | Resolve the interface
Compare multipole host, command wiring and local override for ABB 2CCS800900R0501. Include termination details, adjacent devices, protective clearances and the intended operating state.
If ABB 2CCS800900R0501 is being proposed as a replacement, obtain a written comparison of the old and new designations. Do not rely on the manufacturer prefix alone.
04 | Prepare safe access
Isolate every relevant source before handling ABB 2CCS800900R0501. Capacitors, power semiconductors, control feeds and connected loads may retain hazardous energy.
Follow ABB and site safety procedures for ABB 2CCS800900R0501; confirm the required safe state and document original wiring, polarity, settings and mechanical orientation.
05 | Install and prove
Mount ABB 2CCS800900R0501 only in its approved host and restore all covers, bonding and terminal clearances. Then test remote and local operating states.
Record measured results for ABB 2CCS800900R0501, including normal and fault-state behavior. A lit indicator or a cleared alarm alone is not a complete acceptance test.
06 | Close the maintenance record
Keep ABB 2CCS800900R0501 serial or revision information, delivery label and the as-left drawing with the equipment history.
If ABB 2CCS800900R0501 has any variant boundary, carry that note into the spare-parts register so later purchases do not silently substitute another code.
Order closeout
For ABB 2CCS800900R0501, retain the approved order identity, delivery check and commissioning record.
Future ABB 2CCS800900R0501 enquiries should include the original host and circuit constraints.