ABB 2CCS800900R0211 installation dossier
ABB 2CCS800900R0211 is a shunt-operation release accessory in the S800-SOR shunt releases group. The shared category image is a reference, not proof of the exact supplied unit.
For ABB 2CCS800900R0211, the order code and verified manufacturer description establish the article. Circuit ratings and compatibility must also match the installed equipment.
Technical identification and installation limits
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 2CCS800900R0211 |
| Product family | S800-SOR shunt releases |
| Component role | shunt-operation release accessory |
| Exact ABB order reference | 2CCS800900R0211 |
| ABB product series | S800-SOR shunt releases |
| ABB order code | 2CCS800900R0211 |
| Manufacturer designation | S800-SOR250 |
| Control supply | 110–250 V AC/DC in ABB description |
| Host family | S800 high-performance breaker accessories |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
01 | Identify the circuit
Locate ABB 2CCS800900R0211 on the approved single-line, control or service drawing. Record what the part is expected to provide the designed remote trip.
For ABB 2CCS800900R0211, note the real host equipment and duty. A related order code can have a different current, supply, contact layout, kit count or physical fit.
03 | Purchase with evidence
Put ABB 2CCS800900R0211 in full on the purchase line. Attach a photograph of the installed nameplate and the approved drawing revision.
Before dispatch, confirm ABB 2CCS800900R0211 packaging, revision and supplied accessories. A supplier's generic family photo cannot verify the selected variant.
02 | Resolve the interface
Compare breaker host, control supply and trip wiring for ABB 2CCS800900R0211. Include termination details, adjacent devices, protective clearances and the intended operating state.
If ABB 2CCS800900R0211 is being proposed as a replacement, obtain a written comparison of the old and new designations. Do not rely on the manufacturer prefix alone.
04 | Prepare safe access
Isolate every relevant source before handling ABB 2CCS800900R0211. Capacitors, power semiconductors, control feeds and connected loads may retain hazardous energy.
Follow ABB and site safety procedures for ABB 2CCS800900R0211; confirm the required safe state and document original wiring, polarity, settings and mechanical orientation.
06 | Close the maintenance record
Keep ABB 2CCS800900R0211 serial or revision information, delivery label and the as-left drawing with the equipment history.
If ABB 2CCS800900R0211 has any variant boundary, carry that note into the spare-parts register so later purchases do not silently substitute another code.
05 | Install and prove
Mount ABB 2CCS800900R0211 only in its approved host and restore all covers, bonding and terminal clearances. Then prove commanded trip and reset indication.
Record measured results for ABB 2CCS800900R0211, including normal and fault-state behavior. A lit indicator or a cleared alarm alone is not a complete acceptance test.
Order closeout
For ABB 2CCS800900R0211, retain the approved order identity, delivery check and commissioning record.
Future ABB 2CCS800900R0211 enquiries should include the original host and circuit constraints.