ABB 1SFN030300R1000 procurement and technical comparison
ABB 1SFN030300R1000 is the representative purchasing reference for VM mechanical contactor interlocks. Start by checking the installed duty and full designation. A code grouped on this page may have a different rating or function and is not automatically interchangeable.
Verified technical parameters
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 1SFN030300R1000 |
| Product family | VM mechanical contactor interlocks |
| Component role | mechanical interlock accessory |
| Exact ABB order reference | 1SFN030300R1000 |
| ABB product series | VM mechanical contactor interlocks |
| ABB type | VM19 |
| Function | Mechanical interlock |
| Pairing | For matched AF contactor combinations |
| Related | VM205/265 is a different frame-matching version |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
For ABB 1SFN030300R1000, the table identifies facts supported by ABB technical material. Confirm all selectable ratings, approvals and order suffixes against the physical unit before release.
03 | Adjacent equipment
Map the upstream supply and the downstream equipment served by ABB 1SFN030300R1000. Review connectors, terminals, panel access, protective earth and accessories as applicable.
ABB 1SFN030300R1000 must fit the complete installation, not just one published nominal value. Ask the responsible engineer to resolve every interface discrepancy.
01 | What the item does
ABB 1SFN030300R1000 is specified to mechanically inhibit simultaneous contactor closure. Capture the asset tag and the actual connected circuit or process before asking for a quotation.
The operating role of ABB 1SFN030300R1000 should be cross-checked with the drawing and functional description; appearance alone is not sufficient.
02 | Exact-match questions
Before ordering ABB 1SFN030300R1000, compare both contactor frames, orientation and interlock kit. Preserve the whole designation, including spaces, suffixes and revision information.
When another ABB 1SFN030300R1000 family code is offered, record every changed contact, voltage, mounting, communication or material condition.
04 | Commercial check
Request ABB 1SFN030300R1000 with its complete part string, quantity, approved condition and required documentation. Ask the supplier to identify any supersession separately.
Keep the ABB 1SFN030300R1000 quote, label image and manufacturer data together so the receiving team can compare like with like.
06 | Installation boundary
Service work on ABB 1SFN030300R1000 requires the site's isolation, permit and qualification procedures. Record the prior wiring and settings before disturbing the old item.
Fit ABB 1SFN030300R1000 only with the specified mounting hardware and accessories. Do not infer a safe connection from similar catalog photographs.
05 | Receipt and storage
Inspect ABB 1SFN030300R1000 on arrival for marking, damaged terminals, broken seals and missing companions. Hold ambiguous stock until the engineering owner confirms it.
If ABB 1SFN030300R1000 needs controlled storage, retain its protective packaging and follow the manufacturer's environmental instructions.
07 | Acceptance evidence
After fitting ABB 1SFN030300R1000, test blocked and permitted operations. Test the full connected function through normal and fault-relevant states as the site procedure requires.
Document the ABB 1SFN030300R1000 results, as-left configuration and reviewer; an untested replacement should not be released for service.
08 | Future replacement
Archive ABB 1SFN030300R1000 with the drawing revision, manufacturer document and test record. This keeps later stock decisions tied to the actual installation.
Re-evaluate any future ABB 1SFN030300R1000 variant against that record instead of assuming that a common series name guarantees compatibility.
Same-series codes grouped on this page
These ABB 1SFN030300R1000 related codes are covered here and will not get separate product pages. They may differ in rating, fit, controls or function; verify the exact designation before ordering or substitution.
- 1SFN035203R1000
Release checklist
Release ABB 1SFN030300R1000 only after identity, application, fit and acceptance evidence agree.
Retain the ABB 1SFN030300R1000 decision record for the next procurement and maintenance cycle.