ABB 1SBL297201R1300 switching-path review
Use this switching-path record to decide whether ABB 1SBL297201R1300 matches the intended control circuit and mechanical assembly.
Verified technical data
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 1SBL297201R1300 |
| Product family | AF38-40-00-13 |
| Component role | four-NO AF38 power contactor |
| Exact ABB order code | 1SBL297201R1300 |
| Product series | AF38-40-00-13 |
| Main poles | 4 NO |
| Auxiliary | None in -00 layout |
| Control | 100–250 V AC/DC for -13 |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The ABB 1SBL297201R1300 parameters above come from the cited ABB source. Verify any option-dependent value on the delivered unit before energizing it.
1. Confirm the ordering identity
Record the complete ABB 1SBL297201R1300 code from the marking, quotation and approved drawing. An ABB series name alone cannot establish the supplied coil or contact arrangement.
Treat ABB 1SBL297201R1300 as the precise purchasing identity, including suffixes. A product photograph is a reference, not proof of the exact delivered configuration.
3. Match the actuator supply
Compare the ABB 1SBL297201R1300 control-coil code to measured supply voltage, frequency or DC source. Distinct coil suffixes within a family are not plug-in equivalents by assumption.
For ABB 1SBL297201R1300, check coil version, line current and four-pole protection; preserve a record of the verified coil marking and control-source rating.
2. Draw the current and signal paths
Map the conductors that ABB 1SBL297201R1300 will switch and the indication path returning to the controller. The intended job is to switch a four-pole circuit.
Before installing ABB 1SBL297201R1300, check the real load, utilization category, contact plan and any required protective device in the full circuit.
5. Commission the entire assembly
After safe isolation and installation by qualified personnel, verify four-pole operation. Check normal operation, release and relevant failure indication.
An ABB 1SBL297201R1300 acceptance record should include the commanded sequence, contact-state observations and the protective-system result.
4. Test mechanical and accessory fit
Verify ABB 1SBL297201R1300 dimensions, mounting, terminal access, interlocks and accessory-block fit against the panel drawing and manufacturer instructions.
Check the enclosure clearances for ABB 1SBL297201R1300, not only the face dimensions. Specify optional auxiliary blocks separately where the control design needs them.
6. Decide on substitutions explicitly
If ABB 1SBL297201R1300 is unavailable, compare the suggested alternative's coil, main poles, auxiliary contacts, duty, approvals, mounting and wiring one field at a time.
Do not mark another code as an automatic replacement for ABB 1SBL297201R1300; secure engineering approval and keep the differences with the equipment record.
Same-series order codes kept on this page
The following codes are associated with ABB 1SBL297201R1300 and will not receive separate product pages. Review each complete code, particularly coil suffixes; listing does not imply direct interchangeability.
- 1SBL297201R1400
Release criterion
Release ABB 1SBL297201R1300 for purchase only after the full code, duty, coil and terminal layout agree with the approved design.
File the ABB 1SBL297201R1300 commissioning result, source reference and as-left drawing together for future maintenance.