ABB 1SAZ321201R1005 technical procurement brief
ABB 1SAZ321201R1005 is used to protect a TA75DU motor starter. The checks below help identify the exact article and verify its operating position.
Verified technical data
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 1SAZ321201R1005 |
| Product family | TA75DU-63 |
| Component role | 45–63 A class 10A thermal overload relay |
| Full designation | 1SAZ321201R1005 |
| Product family | TA75DU-63 |
| Setting range | 45–63 A for TA75DU-63 |
| Trip class | 10A |
| Family boundary | Other TA75DU codes have different adjustment ranges |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The ABB 1SAZ321201R1005 figures shown above are tied to the cited ABB reference. Confirm configuration-dependent details on the delivered marking and project documentation.
Engineering evidence to collect
For ABB 1SAZ321201R1005, retain the as-built drawing, host-equipment identity and an image of the removed part. Check the device position against the circuit and the maintenance record.
The ABB 1SAZ321201R1005 code can have adjacent options within its family. State the required electrical and mechanical interfaces explicitly in the request for quotation, even when the old unit is available for comparison.
Procurement decision
Specify ABB 1SAZ321201R1005 by its complete order code, not by an informal family label or appearance. This article is for 45–63 A class 10A thermal overload relay; the buyer should request the exact marking and an applicable manufacturer data sheet.
Before accepting ABB 1SAZ321201R1005, confirm motor nameplate current, upstream protection and contactor fit. A supplier's proposed substitute needs a documented difference review covering fit, ratings, approvals and duty.
Incoming inspection
On delivery, compare the package and device label with ABB 1SAZ321201R1005. Inspect terminals, actuator or housing, accessories and visible damage before taking the equipment out of service.
If the supplied unit differs from ABB 1SAZ321201R1005 in voltage, current range, color, contact arrangement, software entitlement or connection, quarantine it for technical review rather than relying on a similar catalog photograph.
Functional acceptance
After installation of ABB 1SAZ321201R1005, check dial setting, trip and reset. Write down test conditions, expected response and actual response in the handover record.
For ABB 1SAZ321201R1005, include both normal operation and the off-state or alarm condition where applicable. Where a safety function is involved, verify the assembled system rather than only the individual component.
Installation constraints
Plan isolation and stored-energy control before work on ABB 1SAZ321201R1005. Only trained personnel should connect or configure the device in accordance with the host equipment instructions.
Map each ABB 1SAZ321201R1005 lead, terminal, mounting point or software dependency. Verify clearances and separately ordered components, and preserve the original part until the replacement passes acceptance.
Spare-parts decision
Determine whether ABB 1SAZ321201R1005 must be held as a site spare or ordered against a planned shutdown. Consider lead time, repair criticality and storage conditions without assuming a nearby code is equivalent.
If ABB 1SAZ321201R1005 is discontinued, ask ABB or a qualified supplier for a documented successor and compare mounting, wiring and performance before a change is approved.
Maintenance handover
Archive the ABB 1SAZ321201R1005 order code, manufacturer document, as-left setting and dated installation photo with the asset. These records reduce ambiguity at the next service event.
Treat ABB 1SAZ321201R1005 as an exact article for purchasing. Related codes below are enquiry references within the same series, not automatic substitutes; each variant has to be checked against its own parameters.
Other same-series order codes
The following codes appear with ABB 1SAZ321201R1005 in the same product series. Different current ranges, colors, contacts, ratings or accessories can make them non-interchangeable. A code listed here is covered on this page and is not planned as a separate product page.
- 1SAZ321201R1006
Order-release checklist
Release an ABB 1SAZ321201R1005 order only after its complete code, duty and connection have been cross-checked with the equipment record.
After work on ABB 1SAZ321201R1005, retain the acceptance evidence with the asset and update the spare record.