ABB 1SAX341001R1101 EF96-100: Exact Order Code, Ratings and Commissioning

description:Technical identification and selection guidance for ABB 1SAX341001R1101, including verified family data, system compatibility and configuration checks....
BASIC INFO

ABB 1SAX341001R1101 application and verification guide

Use the following decision gates to specify ABB 1SAX341001R1101 for an existing installation and to accept the delivered unit against the engineering record.

Key technical parameters

Technical itemVerified value / selection note
Complete designation1SAX341001R1101
Product familyEF96-100
Component role36–100 A self-supplied electronic overload relay
Complete order code1SAX341001R1101
ABB product seriesEF96-100
Setting range36–100 A
Trip class10E, 20E or 30E selectable
Direct-fit familyAF80–AF96 contactors; verify exact host
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

The values for ABB 1SAX341001R1101 derive from the linked ABB product information. Check the delivered label and application-specific limits before use.

Gate 1 — identity and duty

ABB 1SAX341001R1101 is intended to protect the matching AF motor starter. Obtain the full article code from the device or approved drawing before placing the order; the series name alone does not define its rating or options.

Compare ABB 1SAX341001R1101 with the original circuit duty, switching frequency, fault level and environmental conditions. An adjacent number in the series can be a different electrical part even when the housing looks alike.

Gate 2 — electrical interface

Check the ABB 1SAX341001R1101 current, voltage and contact or I/O arrangement against the installed circuit. Trace every supply and feedback conductor, then note required auxiliary devices or overload protection.

For ABB 1SAX341001R1101, verify current dial, trip class, reset and contactor. Do not infer a replacement from a photograph or a broad product-family claim.

Gate 3 — mechanical interface

Review ABB 1SAX341001R1101 mounting width, terminal access, cable bend space and enclosure clearance before the shutdown. A different generation may reposition connectors or change accessories.

Keep the ABB 1SAX341001R1101 host equipment and wiring diagram in the work pack. If the original assembly has add-on blocks or busbar links, confirm their compatibility separately.

Gate 4 — settings and coordination

Record every relevant ABB 1SAX341001R1101 current dial, trip class, reset mode, control supply or fieldbus setting. Compare them with the approved protection study rather than copying a nearby machine's settings.

Where ABB 1SAX341001R1101 is magnetic-only, provide the separately designed overload function. Where it is a controller, retain the configuration and network files needed for restoration.

Gate 5 — acceptance test

After qualified personnel install ABB 1SAX341001R1101, test trip and alarm indication. Capture the test method, actual results and any revised settings in the commissioning record.

For ABB 1SAX341001R1101, check the normal state, commanded change and fault or off-state as applicable. Return the circuit to service only after the assembled function is accepted.

Gate 6 — spare governance

Archive the ABB 1SAX341001R1101 label photo, manufacturer document and as-left record with the asset. If the unit later becomes unavailable, request a written successor comparison rather than silently changing the order code.

The ABB 1SAX341001R1101 page is a purchasing reference for the exact marked article. Same-series alternatives are grouped below only as enquiry references; their settings and interfaces still need individual checking.

Release and handover

Before buying ABB 1SAX341001R1101, confirm exact marking, interfaces and approved settings with the site engineer.

After fitting ABB 1SAX341001R1101, save the test evidence and update the equipment spare record.

 

 

Pre:ABB EF65-70 1SAX331001R1101 | Motor-Control Specification and Duty Review Next:Industrial Panel Selection for ABB EF146-150 1SAX351001R1101