Industrial Panel Selection for ABB MO165-25 1SAM461000R1013

description:Technical identification and selection guidance for ABB 1SAM461000R1013, including verified family data, system compatibility and configuration checks....
BASIC INFO

ABB 1SAM461000R1013 application and verification guide

Use the following decision gates to specify ABB 1SAM461000R1013 for an existing installation and to accept the delivered unit against the engineering record.

Key technical parameters

Technical itemVerified value / selection note
Complete designation1SAM461000R1013
Product familyMO165-25
Component role25 A magnetic-only manual motor starter
Complete order code1SAM461000R1013
ABB product seriesMO165-25
Rated current25 A
ProtectionMagnetic short-circuit only
ABB catalog trip current375 A
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

The values for ABB 1SAM461000R1013 derive from the linked ABB product information. Check the delivered label and application-specific limits before use.

Gate 1 — identity and duty

ABB 1SAM461000R1013 is intended to provide short-circuit switching in the MO165 feeder. Obtain the full article code from the device or approved drawing before placing the order; the series name alone does not define its rating or options.

Compare ABB 1SAM461000R1013 with the original circuit duty, switching frequency, fault level and environmental conditions. An adjacent number in the series can be a different electrical part even when the housing looks alike.

Gate 2 — electrical interface

Check the ABB 1SAM461000R1013 current, voltage and contact or I/O arrangement against the installed circuit. Trace every supply and feedback conductor, then note required auxiliary devices or overload protection.

For ABB 1SAM461000R1013, verify separate overload provision, fault rating and wiring. Do not infer a replacement from a photograph or a broad product-family claim.

Gate 3 — mechanical interface

Review ABB 1SAM461000R1013 mounting width, terminal access, cable bend space and enclosure clearance before the shutdown. A different generation may reposition connectors or change accessories.

Keep the ABB 1SAM461000R1013 host equipment and wiring diagram in the work pack. If the original assembly has add-on blocks or busbar links, confirm their compatibility separately.

Gate 4 — settings and coordination

Record every relevant ABB 1SAM461000R1013 current dial, trip class, reset mode, control supply or fieldbus setting. Compare them with the approved protection study rather than copying a nearby machine's settings.

Where ABB 1SAM461000R1013 is magnetic-only, provide the separately designed overload function. Where it is a controller, retain the configuration and network files needed for restoration.

Gate 5 — acceptance test

After qualified personnel install ABB 1SAM461000R1013, confirm short-circuit scheme and switching. Capture the test method, actual results and any revised settings in the commissioning record.

For ABB 1SAM461000R1013, check the normal state, commanded change and fault or off-state as applicable. Return the circuit to service only after the assembled function is accepted.

Gate 6 — spare governance

Archive the ABB 1SAM461000R1013 label photo, manufacturer document and as-left record with the asset. If the unit later becomes unavailable, request a written successor comparison rather than silently changing the order code.

The ABB 1SAM461000R1013 page is a purchasing reference for the exact marked article. Same-series alternatives are grouped below only as enquiry references; their settings and interfaces still need individual checking.

Other order codes in this series

These designations are listed under ABB 1SAM461000R1013 as related same-series variants. They may differ in current, supply, contacts or equipment generation, and are not presumed interchangeable. A code included here is not assigned a separate product page.

  • 1SAM461000R1015

Release and handover

Before buying ABB 1SAM461000R1013, confirm exact marking, interfaces and approved settings with the site engineer.

After fitting ABB 1SAM461000R1013, save the test evidence and update the equipment spare record.

 

 