Field selection notes for ABB 1SAJ263000R0100
ABB 1SAJ263000R0100 is an exact ordering reference for PROFINET communication interface. Confirm its application and article identity before treating another series member as equivalent.
Technical data and selection limits
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 1SAJ263000R0100 |
| Product family | PNU32.0 |
| Component role | PROFINET communication interface |
| Complete designation | 1SAJ263000R0100 |
| Device family | PNU32.0 |
| Network | PROFINET |
| Controller | ABB UMC100.3 application; confirm firmware |
| Identity | Order article 1SAJ263000R0100 |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The ABB 1SAJ263000R0100 data above are tied to the cited manufacturer reference where stated. Verify all option-dependent values against the delivered label and equipment documentation.
Purpose in the installation
The specified ABB 1SAJ263000R0100 is intended to integrate the motor controller with the engineered PROFINET network. Start with the asset tag and the original circuit or network drawing so the procurement request addresses the right service position.
Before ordering ABB 1SAJ263000R0100, identify the process or motor-control consequence of a missing, failed or changed component. A same-size device may still have different wiring, firmware or operating behavior.
Interface and configuration match
For ABB 1SAJ263000R0100, verify device name, IP plan, controller firmware and GSDML. Also compare supply, connections, mounting and ambient conditions at the actual cabinet or field location.
Where ABB 1SAJ263000R0100 communicates with a controller or fieldbus, confirm software support and the configured address or device name. Where it is an electrical accessory, confirm ratings and coordination.
Read the whole identity
Record the complete ABB 1SAJ263000R0100 designation, the marked article code, hardware revision and any approval label. Photograph the installed item and compare those details with the purchase request.
If the nameplate does not support the ABB 1SAJ263000R0100 description, stop the substitution decision and use the OEM bill of materials or engineering change record to resolve it.
Preparation and isolation
Plan the ABB 1SAJ263000R0100 change with the site's lockout, stored-energy and permit rules. Save parameters and diagnostic evidence if the component forms part of a programmable system.
Label every connection on ABB 1SAJ263000R0100 before removal. Protect plug pins, terminal threads and optical or network connectors from contamination during handling.
Acceptance at the site
After ABB 1SAJ263000R0100 is installed, prove status, commands and network fault diagnostics. Check the healthy state, alarms and response to a controlled fault as permitted by the site's procedure.
Keep the ABB 1SAJ263000R0100 as-left settings, measured values and sign-off together. Release the asset only after its normal control or protection sequence has been observed.
Receipt and installation
At goods receipt, compare the delivered ABB 1SAJ263000R0100 code, packaging and included accessories with the approved order. Do not rely on the seller's short description alone.
Fit ABB 1SAJ263000R0100 with the specified cable, terminal unit, orientation and tightening instructions. Record any deviation from the old assembly for engineering review before energization.
Supplier and maintenance handover
A request for ABB 1SAJ263000R0100 should include the full model string, quantity, asset tag and required delivery condition. Require explicit disclosure of any offered alternative.
File the ABB 1SAJ263000R0100 purchase confirmation, delivered label and acceptance results with the maintenance record so later replacements use verified evidence.
Related configuration references
The following PNU32.0 notation is grouped with ABB 1SAJ263000R0100 for enquiry only. Compare exact options, rating and connector fit; listing is not proof of interchangeability.
No other unassigned PNU32.0 code is grouped with ABB 1SAJ263000R0100 in this release.
Closeout checklist
Confirm the final ABB 1SAJ263000R0100 article, installation position and test record against the purchase requirement.
Retain the ABB 1SAJ263000R0100 acceptance and approval trail for the next maintenance cycle.